5700-E Softener Installation & Startup Guide
Page 19
www.cleanwaterstore.com
Rev 091514
Advanced Menus Continued..
After selecting the mode, the
time of day the unit is set to
regenerate will appear.
Pressing the Regen button will
allow the time to be changed.
Use the up and down arrows to
adjust the hours and A.M. and
P.M. settings.
Pressing the gear again will bring
you to phase 1, Backwash. BW
will be present and P1-10 will be
flashing.
Total minutes spent in backwash
will be flashing. The unit can be
programmed for 0-99 minutes.
The recommended setting for a
softener is 10 minutes
Next menu displays brine draw
settings. BD will be present and P2-
60 will be flashing.