12
Figure 7- Sensor without fittings
Figure 8 - Sensor with Fittings
Adjusting Last Fitting Sensor Position –
By adjusting the sensor up or down, you can position the
sensor properly. Using five (5) thin strips of paper, make a spacing gauge for the Last Fitting Sensor.
(Figure 2.7.3)
Figure 9 – Unit with 5 strips of paper
Figure 9.1 – Verifying LFS light “ON”
When four (4) strips of paper are inserted between the magazine and the top of the magazine rack, the
Last Fitting Sensor light should be on. (Figure 9.1)
If the Last Fitting Sensor does not light with four (4) strips of paper, use a 3mm Metric Hex
Wrench (T Handle preferred) to adjust the sensor position upwards (turn the adjustment screw
clockwise) until the Last Fitting Sensor light turns on. (Figure 9.2 & 9.3)
Fitting detected
Sensor Power
Four (4) strips
of paper
Last Fitting
Sensor Light
On