Features 

1.

 

Destroys monocellular organisms like 

viruses

 and 

bacteria

 with UV light. 

2.

 

Filters 

pollen, dust 

and 

smoke

 indoors through ionization and electrostatic linking, even binds 

particulate matter with a size of 0, 01 µm / micrometers.  

3.

 

Fan can be turned on and off for a silent air purification, ideal for the bedroom.  

4.

 

Ionizes indoor air for better air quality.  

5.

 

The  device  is  equipped  with filters that  do not  need  to  be  replaced  but  can  easily be  cleaned 

regularly.  

6.

 

Stylish, compact and energy saving device.  

7.

 

For rooms up to 60m²/150m³. 

8.

 

If you position the device in a smaller room like the bedroom regulate the air purifier into its 

lowest position „LOW“. 

 

 

 

Security indications 

Take the following steps to minimize the risk of personal injury caused by for example electric shocks 

or fire.  

 

1.

 

Only use the device indoors.  

2.

 

Pull the plug when you do not use the device or when you clean internal or external parts of it.  

3.

 

Use, maintain and clean the device as described in this manual.  

4.

 

Do not use the device when there is visible damage on the electrical cord, the UV lamp or on the 

device itself. Do not repair the device yourself in case of damage.  

5.

 

Make sure that the air outlets are always free, clean up dust, hair and other obstruction for the 

airflow and at the air outlets.  

6.

 

Keep your hair, clothes, jewels or fingers away from the air outlets.  

7.

 

Do not use  the  device  in  rooms  where  inflammable  liquids  or  gases are  stored,  close to  heat 

sources or in particularly humid rooms like the bathroom. 

8.

 

Touch the device only with dry hands.  

9.

 

Pay attention to damages on the electrical cord. Never pull the device by its cord. 

10.

 

Bring discarded devices to the appropriate collecting points. Prevent children from opening the 

device. The device is not a toy. Children may only use the device under the surveillance of an 

adult.  

11.

 

Do not clean the device with a vacuum cleaner. 

12.

 

The UV-C lamp in the device produces UV-C radiation which can be harmful for skin and eyes 

during direct contact. Never look directly into the UV-C lamp and never put your face close to the 

grid at front side or the backside. Stay at least 30 cm away from the air purifier. If you stand 

closer to the device for a short time, then there is no danger. Never use the lamp for any other 

purposes.  

13.

 

Just like other ionization devices, this air purifier produces very small amounts of ozone (< 0, 05 

particles per million). This substance can also naturally be found in the atmosphere and the levels 

reached by the CA-401 do not harm human health. If you are worried please consult your doctor.  

Summary of Contents for Optima CA-401

Page 1: ...izer Air Purifier CA 401 Manual Thank you for having chosen the Clean Air Optima air purifier CA 401 Read these instructions carefully before you start using the purifier and keep the manual for later usage Copyright Clean Air Optima ...

Page 2: ...idable health threat The air purifier by Clean Air Optima offers an affordable and efficient answer to the problem Various filter technologies are combined within this air purifier The device destroys monocellular organisms like viruses and bacteria with UV light Air purifiers by Clean Air Optima facilitate an effective filtration of dust suspended matter gaseous pollutants particles and pathogeni...

Page 3: ...3 Technical Diagram Clean Air Optima CA 401 Electrostatic filter ON OFF button Opening button Front side grid Air outlet Fan Back side grid Air inlet Integrated UV lamp Foot Control panel ...

Page 4: ...e air outlets are always free clean up dust hair and other obstruction for the airflow and at the air outlets 6 Keep your hair clothes jewels or fingers away from the air outlets 7 Do not use the device in rooms where inflammable liquids or gases are stored close to heat sources or in particularly humid rooms like the bathroom 8 Touch the device only with dry hands 9 Pay attention to damages on th...

Page 5: ...seconds and pauses for 105 seconds MED The air purifier produces negative oxygen ions for 60 seconds and pauses for the next 60 seconds HI The air purifier produces continuously negative oxygen ions Choose the right setting depending on the size of the room and the degree of air pollution 3 Press in the TIMER button to set the time for 1 2 3 4 5 6 or 7 hours The LEDs on the right side of the butto...

Page 6: ...ttons on the device The batteries must be placed correctly before you start to use the remote Placing and replacing the batteries 1 Open the section for the batteries at the backside of the remote control 2 Position the button cell CR 2032 and pay attention to the correct polarization positive negative 3 Close the battery case Pulling out and putting back the rustproof electrostatic filter To pull...

Page 7: ...lace the lamp you can order a new one under https www cleanairoptima com productslist accessoires Cleaning of the ionizer rail The UV plasma ionizer air purifier CA 401 possesses a cleaning mechanism to scrape clean the rail of the ionizer The scraping takes place when the electrostatic filter is taken out and put back into the device Normally we advise to clean the filter once a week In order to ...

Page 8: ... of electrical and electronic devices The symbol on the product the manual or the packaging indicate the procedure The material is reusable according to its labelling By recycling the material and reusing the devices you contribute to the protection of our environment Please ask your municipality for the responsible collection point or disposal location ...

Page 9: ...or other forms of handling the device which are not described in this manual do not fall under this guarantee Moreover legal provisions concerning consumer sales are entering into force In case of device failure we advise to return it together with the original receipt and a short description of the deficiency Please contact your retailer or Clean Air Optima if possible If the problem is not a mat...

Page 10: ...C wavelength 254nm Longevity UV lamp 8 000h Fan levels 1 not regulation Airflow max 50 m3 h Volume 25db A Ideal for rooms up to 60m2 150m Power supply AC 220V 50Hz Timer 1 2 3 4 5 6 and 7 hours Colors Dark grey with light gray grid Energy consumption 25 watt Dimensions H 760mm x B 200mm x D 267mm Weight 4 35 kg ...

Page 11: ...11 ...

Reviews: