OPERATION & MAINTINENCE INSTRUCTIONS FOR 

CAP18 

Pass Thru Air Lock Cleanroom Entry System 

Summary of Contents for CAP18

Page 1: ...5445 763 425 9122 800 423 9728 Fax 763 425 2004 E Mail sales cleanairproducts com www cleanairproducts com Engineering Solutions with Value and Integrity OPERATION MAINTINENCE INSTRUCTIONS FOR CAP18 Pass Thru Air Lock Cleanroom Entry System ...

Page 2: ...ng and maintaining the CAP18 Follow all instructions for set up operation and use Operate ONLY from the type of power source indicated If you are unsure of the type of power available to you contact your dealer or power company This unit may be equipped with a polarized alternating current AC plug with one blade wider than the other This plug will only fit into the power outlet one way for safety ...

Page 3: ...ous non explosive environment with non condensing air NEVER put objects into the blower Do not operate blower without metal blower guard Review application with your safety commissioner for proper use Installation Notes Pass thrus must be installed in a flat and level wall capable of supporting the weight of the pass thru Weight depends on size model and options package The pass thru should be wel...

Page 4: ...om Entry System www cleanairproducts com 4 Standard Wall Mounted Pass Thru Installation Before installation locate all mounting frames and mounting frame hardware The notched frame pieces attach to the vertical sides of the pass thru Wall mounted pass thrus featuring universal mounting frames can be installed in a variety of configurations as outlined below ...

Page 5: ...plywood base remove any screws attaching it to the pallet Then slide the pass thru off the edge of the pallet and remove the 4 bolts attaching the plywood base located near each corner These bolts thread into a nut plate within the pass through walls Installation Remove both of the interior side panels and all shipping braces from within the cabinet At this point the interior nut plate can also be...

Page 6: ...h the 7 16 holes within the pass thru wall cavity into the floor for anchor bolts Clean Air Products does not provide anchoring hardware The shipping braces and shims should still be installed during this step Final Assembly Once the pass thru is fully secured and functioning within the wall remove the shipping braces and reinstall the interior side panels Adjust floor sweeps if needed by loosenin...

Page 7: ...se can be anchored to a variety of wall types Below are the most common installation methods The pass thru must be installed plumb and square to ensure proper door alignment Shimming may be necessary to square the cabinet Installation Notes It is recommended that floor mounted fire rated units be anchored to the floor in addition to the wall Maintain clearance between frame return flanges and stud...

Page 8: ...opposite side automatically as soon as a door is opened Magnetic Interlocks If your pass thru is equipped with magnetic style interlocks the doors are normally locked The doors are unlocked by an illuminated capacitive touch button When both of the doors are closed the buttons are green the doors can be unlocked If a door is open the buttons are red and the opposite door cannot be unlocked HEPA fi...

Page 9: ...arbonate or acrylic windows wipe them down lightly with soft cleanroom wipes to avoid scratching Verify that any cleaning chemicals used are compatible the with window material before cleaning Once a year check that the pass thru is securely mounted All hardware including perimeter mounting screws should be securely fastened Verify that any cleaning chemicals used are compatible with cabinet mater...

Page 10: ...ment HEPA filters are warranted to have their given efficiency at the time of shipping Parts shipped to replace warranty items shall be invoiced out with 60 day terms Credit shall be issued when defective parts are returned to Clean Air Products factory Contaminated materials shall be credited after receipt of proper disposal is sent to Clean Air Products When special shipping containers are used ...