![Clayton WartHog Safety, Operation & Maintenance Download Page 10](http://html.mh-extra.com/html/clayton/warthog/warthog_safety-operation-and-maintenance_2619874010.webp)
Repair or Warranty Contact
Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084
WH-0
Page 10
4.
Install a new bag filter.
•
Unfold and fluff a new bag filter.
•
Push the inlet tube into the hole on the cardboard collar of the bag filter.
• Grasp the sides of the cardboard collar and push it all the way onto the inlet tube.
• Verify the bottom of the collar is past the opening on the underside of the inlet tube.
5.
Verify the HEPA filter is seated.
•
Holding the power head on its side, examine the HEPA filter.
•
Verify the white inner ring of the HEPA filter is in contact with the underside of the power head.
–
If it is not, turn it clockwise until it comes in contact with the underside of the power head.
6. Replace the primary power head.
• Carefully position the primary power head on the primary tank.
• Toggle the primary vacuum power switch to the OFF position.
• Rotate the power head so that the power switch on the power head is aligned with the inlet port on the vacuum tank.
• Latch the power head to the tank.
• Toggle the support vacuum power switch to the OFF position.
7.
Disconnect the vacuums.
• Disconnect the SFC hose from the primary vacuum’s SFC port.
• Disconnect the SFC hose from the support vacuum’s inlet port.
SAFE FILTER CHANGE
GL_005
Filter Bag
Bottom and top of
Cardboard Bag Collar
must be flush to tank
Push Cardboard Bag Collar
past this point
Tank Wall
Tank Wall