HEAVY DUTY-BUILT FOR YEARS OF RELIABLE USE
•
HIGH STRENGTH STAND PIPE PROVIDES PROTECTION AGAINST DAMAGE
•
STAND PIPE HAS SUPERIOR CORROSION RESISTANCE
•
STEEL, ZINC PLATED ROD FOR LONG LIFE
•
HEAVY DUTY DUAL BYPASS BOTTOM VALVE ALLOWS BETTER FLOW WITH LESS
RISK OF BLOCKAGE FROM DEBRIS
•
COMPONENTS CAN BE REPLACED FROM ABOVE GROUND WITHOUT DIGGING
•
LOCKING EYE HOLES ALLOW HYDRANT TO BE PADLOCKED WHEN NOT IN USE.
•
INLET 3/4” NPT, OUTLET 3/4” GARDEN HOSE THREAD.
ITEM
QTY
DESCRIPTION
MAT'L OF CONSTRUCTION
1
1
HEAD
CAST IRON
2
1
HANDLE
CAST IRON
3 *
1
CONNECTOR
BRASS
4 *
2
LINK
STEEL-ZINC PLATED
5 *
1
FULCRUM BOLT
STEEL-ZINC PLATED
6 *
1
FULCRUM NUT
STEEL-ZINC PLATED
7 *
1
SQUARE HEAD SET SCREW
STEEL-ZINC PLATED
8 *
1
PACKING NUT
BRASS
9 *
1
PACKING
GRAPHITE
10
1
HOSE ADAPTER 3/4"
BRASS
11
1
BOTTOM VALVE
BRASS
12
1
CLEVIS ROD/ROD ASSEMBLY
STAINLESS STEEL/STEEL-ZINC PLATED
13
1
PIPE
STEEL, GALVANIZED
14 *
1
PLUNGER
BUNA-N/BRASS
* ITEMS ARE INCLUDED IN YRK1 REPAIR KIT.
5451 SERIES
FROST-PROOF YARD HYDRANT
HOW A FROST-PROOF HYDRANT WORKS
CLOSED
The hydrant is closed and no water is in the
riser pipe or head. Water is stopped by the
plunger (valve) below the frost line.
Protected like this, no freezing can occur.
CLOSED - DRAINING
Closing the handle pushes the plunger
down to seal off the water and uncover
the drain hole. This allows the water in
the head and riser pipe to drain back
down into the gravel drain bed. The
hydrant is now empty and cannot freeze.
OPEN - WATER FLOWING
Water is made available by raising the handle.
This will lift the plunger allowing water to flow and
the plunger to seal off the drain hole.
®
LEAVE THIS SHEET WITH END USER.
NOTE: WATER FLOW CANNOT BE THROTTLED.
Hydrant handle must be positioned in the FULL
open position for proper water flow and drainback
seal. This hydrant will not operate properly in a
PARTIALLY open position.