background image

ENGLISH 

Draining clear water

 

Model

300

600 

Electrical data

 

P1 Rated absorbed power [W]

300

600

Mains voltage [V]

 

1 ~ 230 AC 

1 ~ 230 AC 

Mains frequency [Hz]

 

50

50

Current [A]

 

1.3

2.5

Capacitor [µF]

 

8

12.5

Capacitor [Vc]

 

450

450

Hydraulic data

 

Max. flow rate [l/min]

 

125 

175 

Max. head [m]

 

6.5 

Max. head [bar]

 

0.65 

0.9 

Max. immersion depth [m]

Min. AUT starting height [mm]

115 

115 

Stopping height [mm]

 

45 

45 

AUT residual water height [mm]

2-3

2-3

Range of use

 

Length of power cable [m]

10 

10 

Type of cable

 

H05 RNF 

H05 RNF 

Grade of motor protection

IP X8 

IP X8 

Insulation class

 

F

F

Liquid temperature range [°C] 

according to EN 60335-2-41 for domestic use

0 °C / +35 °C 

0 °C / +35 °C 

Max. particle dimension [mm]

Ø 5 

Ø 5 

Max. ambient temperature [°C]

+40 °C 

+40 °C 

Weight

 

DNM GAS 

1'' 1/4 M 

1'' 1/4 M 

Net/Gross weight approx. [kg]

4.8 / 5.5 

5.3 / 6 

Table 3 

The pump which does not stand on a base cannot support the weight of the pipes, which must be 
supported in some other way.

 

4. MANAGEMENT

4.1 Storage 

All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust. 
They are supplied in their original pack in which they must remain until the time of installation. 

4.2 

Transport 

Avoid subjecting the products to needless impacts and collisions. 

4.3 Weight 

and 

dimensions 

The adhesive plate on the packaging indicates the total weight of the pump and its dimensions. 

5. WARNINGS

The pumps must never be carried, lifted or allowed to operate suspended from the power cable; use 
the handle provided.

 

The pump must never be allowed to run when dry.

The sealing device contains lubricant which is non-toxic but which may alter the characteristics of the water, in the
case of pure water, if the pump were to have any leaks.

6. INSTALLATION

Screw on the elbow with hosetail fitting provided in the packaging. Use a pipe tightening clamp to secure the pipe to the
fitting.

If the bottom of the trap where the pump is to be placed is particularly dirty, a raised support should be provided so as
to avoid blocking of the suction grid (Fig.1)

Totally immerse the pump in the water.

Ensure that the minimum dimensions of the trap in which it is housed are as follows:

Min. base dimensions (mm) 200x200 / Min. height (mm) 400

The dimensions of the trap must always be in relation to the quantity of water arriving and to the flow of the pump, so
as not to subject the motor to excessive starts/hour; it is strongly recommended not to exceed 20 starts/hour.

The pump must be installed in vertical position! 

Summary of Contents for ProSub 300

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE GB ...

Page 2: ...Pag 1 ENGLISH ...

Page 3: ...Fig Fig Abb Fig Fig Фиг Obr Fig Εικ Joonis Kuva Sl ábra Fig att Afbeelding Fig Rys Fig Fig Схема Obrázok Sl Fig Sl Fig Resim Мал 1 2 3 4 ...

Page 4: ...lecting traps or infiltrations from roof gutters etc Thanks to their compact and handy shape they are also used for particular applications as portable pumps for emergency situations such as for drawing water from tanks or rivers draining swimming pools and fountains excavations or underpasses Also suitable for gardening and general hobby activity These pumps cannot be used in swimming pools ponds...

Page 5: ...l the time of installation 4 2 Transport Avoid subjecting the products to needless impacts and collisions 4 3 Weight and dimensions The adhesive plate on the packaging indicates the total weight of the pump and its dimensions 5 WARNINGS The pumps must never be carried lifted or allowed to operate suspended from the power cable use the handle provided The pump must never be allowed to run when dry ...

Page 6: ...en used with substances that tend to form a deposit or with water containing chlorine rinse it after use with a powerful jet of water in order to avoid the formation of deposits or encrustations which would reduce the characteristics of the pump 10 MAINTENANCE AND CLEANING In normal operation the pump does not require any type of maintenance In any case all repair and maintenance work must be carr...

Page 7: ...an move freely 4 The flow rate is insufficient A Check that the suction grid is not partially blocked B Check that the impeller or the delivery pipe are not partly blocked or encrusted C Ensure that the check valve if contemplated is not partially blocked A Remove any obstructions B Remove any obstructions C Accurately clean the check valve 5 The pump stops after having run for a short time A The ...

Reviews: