Draining dirty water
Model
P1=330
EcoSub 7
Electrical data
P1 Rated absorbed power [W]
330
440
Mains voltage [VJ
220-240 AC
Mains frequency fHzl
50
Current [A]
1.5
1.6
Capacitor [µ F]
8
Capacitor [Vcl
450
Hydraulic data
Max. flow rate fl/minl
130
140
Max. head [m]
5.5
7
Max. head [bar]
0.55
0.7
Max. immersion depth [m]
7
Min. AUT starting height [mm]
260
Min/max. stopping height [mm]
100/150
Residual water height [mm]
10
Range of use
Length of power cable [m]
10
Type of cable
HOS RNF
Grade of motor protection
IPX8
Insulation class
B
Liquid temperature range [
0
C]
0
°CI
+35
°
C
according to EN 60335-2-41 for domestic use
Max. particle dimension fmml
030
Max. ambient temperature f
°
Cl
+40
°
C
Weight
DNM GAS
1"1/4F
N et/Gross weight approx. [kg]
4.2/5.15
4.65 / 5.6
Table 3
� The pump which does not stand on a base cannot support the weight of the pipes, which must be
� supported in some other way.
4. MANAGEMENT
4.1 Storage
All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust.
They are supplied in their original pack in which they must remain until the time of installation.
4.2 Transport
Avoid subjecting the products to needless impacts and collisions.
4.3 Weight and dimensions
The adhesive plate on the packaging indicates the total weight of the pump and its dimensions.
5. WARNINGS
� The pumps must never be carried, lifted or allowed to operate suspended from the power cable; use
� the handle provided.
• The pump must never be allowed to run when dry.
• On the body there is a venting hole to avoid phenomena of cavitation when starting the pump. It is therefore normal
for a small amount of water to come out of the pump during operation. (Fig.1 ).
• The sealing device contains lubricant which is non-toxic but which may alter the characteristics of the water, in the
case of pure water, if the pump were to have any leaks.
6. INSTALLATION
Screw on the elbow with hosetail fitting provided in the packaging. For the dirty water version only the fitting for 30 mm
pipes; if you want to use a pipe with a larger diameter, change the elbow coupling. Use a pipe tightening clamp to secure
the pipe to the fitting.
• It is advisable to use pipes having an internal diameter of 30 mm to avoid the decrease of pump performance and the
possibility of blocking.
• If the bottom of the trap where the pump is to be placed is particularly dirty, a raised support should be provided so as
to avoid blocking of the suction grid (Fig.2)
• Totally immerse the pump in the water.
• Ensure that the minimum dimensions of the trap in which it is housed are as follows:
Min. base dimensions (mm) 460x460 / Min. height (mm) 400
2