background image

180

(7.09")

243

(9.57")

533

(20.99")

Rotating angle

90°

90°

5.  DIMENSIONS

10

TAMBORA FLASH

THE PROJECTOR WILL NOT SWITCH ON

TROUBLE

ELECTRONICS NON-OPERATIONAL

DEFECTIVE PROJECTION

REDUCED LUMINOSITY

POSSIBLE CAUSES

CHECKS AND REMEDIES

No power supply.

LED burnt out or defective.

Signal transmission cable faulty or disconnected.

Incorrect addressing.

Fault in the electronic circuits.

Optic fault.

Dust or grease deposits.

Check the power supply voltage.

Call an authorised technician.

Replace the cables.

Check addresses (see instructions).

Call an authorised technician.

Call an authorised technician.

Clean (see instructions).

6.  CAUSE AND SOLUTION OF PROBLEMS

Summary of Contents for TAMBORA FLASH CL2020

Page 1: ...ur expectations and requirements INDEX ENGLISH Page Contents 2 1 Safety information 3 2 Unpacking and preparation 3 3 Installation and start up 3 3 1 Fixture overview 4 3 2 Installing the fixture 5 3 3 Connecting to mains supply 5 3 4 Connecting the control signal line DMX Art Net 6 3 5 Switching on the fixture and basic SetUp 8 4 Maintenance 8 4 1 Periodical cleaning Caution 9 4 2 Battery 10 5 Di...

Page 2: ...lgendem Link auffindbar www claypaky com Ref FIS02C Safety Information Tambora Flash INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace www claypaky com Ref FIS02C Safety Information Tambora Flash CONSIGNES DE SÉCURITÉ IMPORTANT Cl...

Page 3: ...ontents Fig 1 2 UNPACKING AND PREPARATION 5pin DMX IN THRU Ethernet Neutrik PowerCON TRUE1 IN OUT LCD Display Functional buttons Fan Anti moisture valve Safety loop Fan 2 3 INSTALLATION AND START UP 3 1 Fixture overview Continue ...

Page 4: ...ber feet on a truss on the ceiling or wall WARNING the safety chain must be installed except when the projector rests on the floor Code 105041 001 available upon request This must be secured to the projector support structure and then hooked to the fastening point at the centre of the fixture 3 2 Installing the fixture ...

Page 5: ... low capacity Do not use microphone cable or other cable with characteristics differing from those specified End connections must be made using XLR type 5 pin male female connectors A terminating plug must be inserted on the last projector with a resistance of 120 minimum 1 4 W between terminals 2 and 3 IMPORTANT The wires must not make contact with each other or with the metal casing of the conne...

Page 6: ...key having been pressed the display automatically returns to rest status It should be noted than when this condition occurs any possible value that has been modified but not yet confirmed with the ENTER key will be cancelled 7 3 5 Switching on the fixture and basic SetUp 28 28 Reversal of the display Fig 8 To activate this function press UP and DOWN keys simultaneously while the display is in the ...

Page 7: ...and DOWN keys to select the menu to be used Setup To set the setting options Option To set the operating options Information To read the counters software version and other information Manual Control To trigger the test and manual control functions Test To check the proper functioning of effects Advanced Access to the Advanced menu is recommended for a trained technical personnel 3 Press to displa...

Page 8: ... death For additonal service information please contact service claypaky it IMPORTANT The screws to be removed have rubber sleeve gaskets at the threaded end of the screw DO NOT LOOSE these They must be reinstalled when reassembly is done If these rubber sleeve gaskets are damaged they must be replaced with exact original equipment OE parts we also suggest to replace the rubber sleeve gasket every...

Page 9: ...9 TAMBORA FLASH This product contains a rechargeable battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 10 4 2 Battery ...

Page 10: ...EMEDIES No power supply LED burnt out or defective Signal transmission cable faulty or disconnected Incorrect addressing Fault in the electronic circuits Optic fault Dust or grease deposits Check the power supply voltage Call an authorised technician Replace the cables Check addresses see instructions Call an authorised technician Call an authorised technician Clean see instructions 6 CAUSE AND SO...

Page 11: ...11 TAMBORA FLASH ...

Page 12: ...IST02P EN Rev 0 10 2022 CLAYPAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 www claypaky com ...

Reviews: