background image

5

SHARPY PLUS

Switching on the projector - Fig. 8

Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:

                                         Model                                      Firmware                             xxx (Fixture ID)                      System errors

                                                         SHARPY PLUS                       Version X.X.X                      Dmx Address xxx                 E: .........................

                                                                                                         Date - Hour                                                                        W: .........................

On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit - Tilt 128 bit). The control
panel (Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two
conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address. 

During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the

F

key will be cancelled.

 

 

1

Dmx Address

Warning Message

8

Connecting to the control signal line (DMX) - Fig. 7
Use  a  cable  conforming  to  specifications  EIA  RS-485:  2-pole  twisted,  shielded,  120Ohm  characteristic  impedance,  22-24  AWG,  low  capacity.  Do  not  use
microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 5-pin male/female
connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.
IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the
shield braid and to pin 1 of the connectors.

Connecting to the mains supply - Fig. 6

 

 

 

 

 

 

 

SIGNAL

SCREEN

DMX 512

5 PIN

1

2

3

4

5

SIGNAL

Mains

6

7

Continue  

3.3 Connecting the control signal line: DMX / Art-Net

3.4 Switching on the fixture and basic SetUp

Summary of Contents for SHARPY PLUS

Page 1: ... and basic SetUp 7 4 Maintenance 7 4 1 Opening the covers 8 4 2 Periodical cleaning 9 4 3 Effects module removal 10 4 4 Cleaning of the filters 12 4 5 Rotating gobos 13 4 6 Battery removal 14 5 Specifications PRELIMINARY Congratulations on choosing a Claypaky product We thank you for your custom Please note that this product as all the others in the rich Claypaky range has been designed and made w...

Page 2: ...ndem Link auffindbar www claypaky com Ref FIS01H Safety information Sharpy Plus INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace www claypaky com Ref FIS01H Safety information Sharpy Plus CONSIGNES DE SÉCURITÉ IMPORTANT Claypaky ...

Page 3: ...0 9 0 9 0 9 0 UNLOCKED LOCKED PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 2 3 Packing contents Fig 1 UNLOCKED LOCKED 4 5 4 5 45 4 5 45 4 5 4 5 2 UNPACKING AND PREPARATION ...

Page 4: ...when the projector is positioned on the floor the safety cable must be fitted Cod 105041 003 available on request This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base 3 INSTALLATION AND START UP 3 1 Installing the fixture Light collimation system This product contains internal light collimation system Avoid intense l...

Page 5: ...noted than when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled 1 Dmx Address Warning Message 8 Connecting to the control signal line DMX Fig 7 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance 22 24 AWG low capacity Do not use microphone cable or other cable with charact...

Page 6: ...ons have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press LEFT D once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informations Informations Menu To read the counters software version and other informat...

Page 7: ...g Pan and Tilt movements Refer to the instructions in the UNPACKING AND PREPARATION section Opening the head covers Fig 10 Closing the head covers Fig 11 2 4 1 1 1 4 Turn 3 2 1 4 Turn 10 11 Continue 4 MAINTENANCE 4 1 Opening the covers ...

Page 8: ...ny detergent liquid for cleaning glass to remove the dirt from the reflectors from the lenses and filters It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subject to friction using lubricants specifically supplied by Cla...

Page 9: ...he support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 13 14 and 15 in reverse order NOTE Do not disconnect wiring harnesses when the fixtures is switched on to avoid to damage electronic boards Do not switch on the fixtures with wiring harness disconnected 13 ...

Page 10: ...10 SHARPY PLUS 1 2 3 13 Cleaning of the filters Fig 13 4 4 Cleaning of the filters ...

Page 11: ...must be adjusted with the projector switched off After adjusting close the effects covers switch on the projector and check that the adjustment has been correctly made If necessary switch off the projector remove the effects covers and repeat lamp adjustment REMARK Lifetime of the lamp will be influenced by the switching cycle After a successful starting attempt to keep the lamp burning for at lea...

Page 12: ... 17 Before use custom gobos contact Claypaky The original gobos have a special coating designed specifically to resist to the high temperatures The rotating gobo wheel only use dichroic glass gobos it is not possible to use metal gobos For more information contact Claypaky Gobo orientation Fig 16 The pictures shown the correct gobos orientation Bearing group replacement Fig 15 15 16 17 4 5 Rotatin...

Page 13: ...Battery removal Fig 18 This product contains a rechargeable battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 6 1 4 2 3 5 18 4 6 Battery removal ...

Page 14: ...or mixing 15 colors on 3 wheels 2 CTO filters Rotating Gobo Wheel 8 interchangeable glass gobos Static Gobo Wheel 18 fixed gobos Rotating 4 facet prism on dedicated channel Rotating 8 facet prism on dedicated channel Dynamic Animation disc Linear soft edge frost filter Dimmer and stop strobe Dense Sharp Parallel Light Beams Extremely quick movements Excellent visual effect projections Wide and sha...

Page 15: ... mains supply Lamp exhausted or defective Signal transmission cable faulty or disconnected Incorrect addressing Fault in the electronic circuits Lenses or reflector broken Dust or grease deposited Check the power supply voltage Replace the lamp See instructions Replace the cables Check addresses see instructions Call an authorised technician Call an authorised technician Clean see instructions ...

Page 16: ...CLAYPAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 Fax 39 035 301876 www claypaky it IST01E 001 EN PRELIMINARY 01 2019 ...