Lamp change - Fig 14.
Take the new lamp out of its package and insert in the fitting.
WARNING: do not touch the lamp’s envelope with bare hands. Should this happen, clean the bulb with a cloth soaked in alcohol and dry it
with a clean, dry cloth.
Lamp regulation
To centre the lamp, move the lamp holder as shown in the figure.
WARNING: The lamp must be adjusted with the projector switched off. After adjusting, close the effects covers, switch on the projector and check
that the adjustment has been correctly made. If necessary, switch off the projector, remove the effects covers and repeat lamp adjustment.
REMARK:
- Lifetime of the lamp will be influenced by the switching cycle.
- After a successful starting, attempt to keep the lamp burning for at least 15 minutes in order to complete the chemical cycle of the
lamp to secure the lifetime.
- After switching-off the lamp wait at least 2 minutes before switching-on it again.