background image

5

AXCOR PROFILE 600 - 600 HC

Switching on the projector

- Fig. 8

Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:

        

                                Model                                      Firmware                             xxx (Fixture ID)                      System errors

                                                         Axcor                                      Version X.X.X                      Dmx Address xxx                 E: .........................
                                                         600                                          Date - Hour                                                                        W: .........................

On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit - Tilt 128 bit). The control panel

(Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two conditions:

rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address (if set). 

During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.

It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the

F

key will be cancelled.

 

 

 

 

1

2

Dmx Address

Warning Message

Fixture ID

8

Connecting to the control signal line (DMX)

- Fig. 7

Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use

microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 3 or 5 pin male/female

connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.

IMPORTANT:

The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the

shield braid and to pin 1 of the connectors.

Connecting to the mains supply 

- Fig. 6

 

 

 

 

 

 

 

SIGNAL

SCREEN

DMX 512

5 PIN

1

2

3

4

5

SIGNAL

SCREEN

1

3

2

DMX 512

3 PIN

SIGNAL
SIGNAL

 

 

 

Mains

6

7

Continue  

3.3 Connecting the control signal line: DMX / Art-Net

3.4 Switching on the fixture and basic SetUp

Summary of Contents for AXCOR PROFILE 600

Page 1: ...age Contents 2 1 Safety information 3 2 Unpacking and preparation 4 3 Installation and start up 4 3 1 Installing the fixture 4 3 2 Connecting to manis supply 5 3 3 Connecting the control signal line DMX Art Net 5 3 4 Switching on the fixture and basic SetUp 7 4 Maintenance 7 4 1 Opening the covers 8 4 2 Periodical cleaning 9 4 3 Effects module removal 14 4 4 Cleaning of the filters 16 4 5 Rotating...

Page 2: ... folgendem Link auffindbar www claypaky com Ref FIS00W Safety Information Axcor 600 series INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace www claypaky com Ref FIS00W Safety Information Axcor 600 series CONSIGNES DE SÉCURITÉ IMP...

Page 3: ... HC 1 PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 Packing contents Fig 1 90 9 0 9 0 9 0 UNLOCKED LOCKED 4 5 4 5 45 4 5 45 4 5 4 5 2 x 183102 805 2 UNPACKING AND PREPARATION 2 3 ...

Page 4: ...g on special rubber feet on a truss or on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety cable must be fitted Cod 105041 001 available on request This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base 3 1 Installing the fixture 3 2 Connecting to manis supply ...

Page 5: ...han when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled 1 2 Dmx Address Warning Message Fixture ID 8 Connecting to the control signal line DMX Fig 7 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance 22 24 AWG low capacity Do not use microphone cable or other cable with c...

Page 6: ...entarily activate the display and thus access the settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press F once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informat...

Page 7: ... Pan and Tilt movements Refer to the instructions in the UNPACKING AND PREPARATION section Opening the head covers Fig 10 Closing the head covers Fig 11 1 4 Turn 2 1 CLICK 1 4 Turn 2 1 4 Turn 1 2 1 10 11 Continue 4 MAINTENANCE 4 1 Opening the covers ...

Page 8: ... dirt from the reflectors from the lenses and filters It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subject to friction using lubricants specifically supplied by Claypaky General visual check of the internal component...

Page 9: ...tion of the effect modules Preliminary operations Fig 13 NOTE Do not disconnect wiring harnesses when the fixtures is switched on to avoid to damage electronic boards Do not switch on the fixtures with wiring harness disconnected Continue 4 3 Effects module removal ...

Page 10: ...side 1 3 3 2 14 Extraction of the effect modules Preliminary operations Fig 14 NOTE Do not disconnect wiring harnesses when the fixtures is switched on to avoid to damage electronic boards Do not switch on the fixtures with wiring harness disconnected ...

Page 11: ...ction of the effect modules Fig 15 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 15 16 17 and 18 in reverse order 15 Continue ...

Page 12: ...xtraction of the effect modules Fig 16 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 15 16 17 and 18 in reverse order 16 ...

Page 13: ...ction of the effect modules Fig 17 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 15 16 17 and 18 in reverse order 17 Continue ...

Page 14: ...14 AXCOR PROFILE 600 600 HC Cleaning of the filters Fig 18 2 1 1 4 Turn 3 4 18 4 4 Cleaning of the filters ...

Page 15: ...15 AXCOR PROFILE 600 600 HC 1 1 4 Turn 4 5 2 5 4 3 3 19 Cleaning of the filters Fig 19 Continue ...

Page 16: ...ng gobos max 20 mm image thickness 1 mm Fig 21 Before use custom gobos contact Claypaky The original gobos have a special coating designed specifically to resist to the high temperatures The rotating gobo wheel only use dichroic glass gobos it is not possible to use metal gobos For more information contact Claypaky Bearing group replacement Fig 20 20 4 5 Rotating gobos ...

Page 17: ...ROFILE 600 600 HC This product contains a rechargeable battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 1 3 5 2 4 6 22 4 6 Battery removal ...

Page 18: ...imation wheel interchangeable with fixed gobo wheel Rotating Prism 1 x 4 facet prism indexable on 540 clockwise and counter clockwise rotation at variable speed Variable frost 0 100 linear Color system CMY with gradually insertion Linear CTO Color wheel 5 colors Iris with multiple macros random pulsing Dimmer 16 bit electronic and linear 3 dimmer curves Strobe 25 flash sec electronic instant open ...

Page 19: ......

Page 20: ...Clay Paky S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 Fax 39 035 301876 www claypaky com IST01A 001 EN PRELIMINARY 09 2018 ...