Claypaky Axcor Profile 400 User Menu Download Page 8

 
 

Axcor Profile 400 / Axcor Profile 400 HC – User Menu 

 

Axcor Profile 400 / Axcor Profile 400 HC 

User Menu

 

07/2020

 

INFORMATION MENU 

 

Information – SYSTEM ERRORS 

It displays a list of errors that occurred when the projector 
was turned on. 

Mostra una lista di errori verificatisi dall'accensione del 
proiettore. 

Information – FIXTURE HOURS 

It lets you view projector working hours (total and partial). 

Total counter 
It  counts  the  number  of  projector  working  life  hours  (from 
construction to date). 

Partial counter 
It  counts  the  number  of  projector  partial  working  life  hours 
from the last reset to date. 

Press  OK  to  reset  the  partial  counter.  A  confirmation 
message  appears  on  the  display:  Select  Reset  to  confirm 
or Go Back to undo the operation. 

Permette  di  visualizzare  le  ore  di  funzionamento  (totali  e 
parziali) del proiettore. 

Total counter 
Conta  il  numero  di  ore  di  vita  del  proiettore  (dalla 
costruzione ad oggi). 

Partial counter 
Conta  il  numero  di  ore  parziali  di  vita  del  proiettore 
dall’ultimo azzeramento ad oggi. 

Premere OK per resettare  il contatore parziale, sul display 
appare  un  messaggio  di  conferma,  selezionare  Reset  per 
confermare oppure Go Back per annullare l’operazione  

Information – LED HOURS 

It lets you view LED working hours (total and partial). 

Total counter 
It  counts  the  number  of  projector  working  hours  with  the 
LED on (from construction to date). 

Partial counter 
It counts the number of LED partial working hours from the 
last reset to date. 

Press  OK  to  reset  the  partial  counter.  A  confirmation 
message  appears  on  the  display:  Select  Reset  to  confirm 
or Go Back to undo the operation. 

Permette  di  visualizzare  le  ore  di  funzionamento  (totali  e 
parziali) dei LED. 

Total counter 
Conta il numero di ore di funzionamento del proiettore con 
LED accesi (dalla costruzione ad oggi). 

Partial counter 
Conta  il numero di ore di funzionamento dei  LED  lampada 
dall’ultimo azzeramento ad oggi. 

Premere OK per resettare  il contatore parziale, sul display 
appare  un  messaggio  di  conferma,  selezionare  Reset  per 
confermare oppure Go Back per annullare l’operazione.. 

Information – SYSTEM VERSION 

It  lets  you  view  the  hardware  and  software  versions  for 
each electronic board in the projector. 

 

Disp 

 

Net 

 

Ctr1-XY 

 

Ctr2-Motor 

 

Ctr3-Motor 

 

Ctr4-Motor 

Permette  di  visualizzare  la  versione  'software'  di  ciascuna 
scheda elettronica presente nel proiettore. 

 

Disp 

 

Net 

 

Ctr1-XY 

 

Ctr2-Motor 

 

Ctr3-Motor 

 

Ctr4-Motor 

Information – DMX MONITOR 

It lets you view the level of projector DMX channels in bit. 

Permette  di  visualizzare  il  livello  dei  canali  DMX  del 
proiettore in bit. 

Information – FANS MONITOR 

It  lets  you  view  the  percentage  of  each  fan  installed  in  the 
projector: 

 

Base Fan (Base cooling fan) 

 

Led Fan (LED cooling fan) 

Permette  di  visualizzare  la  percentuale  di  ogni  ventola 
installata nel proiettore: 

 

Base Fan (ventola per raffreddamento Base) 

 

Led Fan (ventola raffreddamento LED) 

 
 

 

Summary of Contents for Axcor Profile 400

Page 1: ...Main Menu Level 1 Level 2 Level 3 Choices Values SET UP DMX Address 001 512 Ethernet Interface Custom IP Address IP address byte 1 000 255 IP address byte 2 000 255 IP address byte 3 000 255 IP address byte 4 000 255 Custom IP Mask IP mask byte 1 000 255 IP mask byte 2 000 255 IP mask byte 3 000 255 IP mask byte 4 000 255 Universe 000 255 Start Channel 001 512 Ethernet to DMX No Yes ...

Page 2: ... 180 degrees 270 degrees Tilt Home Def Pos 0 12 5 25 50 75 87 5 100 Color Color Mixing RGB CMY Fix Wheel Shortcut On Off CMY Speed Normal Fast Dimmer Curve Dimmer Curve 1 Dimmer Curve 2 Dimmer Curve 3 Dimmer Curve 4 Display On Off Fan Mode Auto SLN Theatre Constant Setting Default Preset Reset To Default Go Back Are you sure Yes No User Preset 1 Load preset 1 Save to preset 1 Are you sure Yes No U...

Page 3: ...rs Read Reset System Version Disp Fw rev Net Fw rev Ctr1 XY Fw rev Ctr2 Motor Fw rev Ctr3 Motor Fw rev Ctr4 Motor Fw rev DMX Monitor Channels Bit Fans Monitor Base Fan Led Fan Network parameters IP Address IP Mask MAC Address UID UID xxxxxxxxx MANUAL CONTROL Reset Yes No Channel Bit Value TEST Pan Tilt Colour Beam Gobo Shutter All ADVANCED Access Code 1234 Upload Firmware Transfer Are you sure Yes...

Page 4: ...tare l indirizzo IP in base alla centralina di controllo utilizzata Custom IP Mask Permette di selezionare la Subnet Mask dell indirizzo IP Setup UNIVERSE It lets you set the DMX Universe to be assigned to a series of projectors with values between 000 and 255 A single DMX512 frame of 512 channels is referred to as a Universe Permette di impostare l universo DMX da assegnare ad una serie di proiet...

Page 5: ... input signal selecting one from the 7 available positions 0 12 5 25 50 75 87 5 100 Invert Pan Permette di abilitare ON l inversione del movimento Pan Selezionare OFF per non abilitare o disabilitare questa opzione Invert Tilt Permette di abilitare ON l inversione del movimento Tilt Selezionare OFF per non abilitare o disabilitare questa opzione Swap Pan Tilt Permette di abilitare ON l inversione ...

Page 6: ...l verso che richiede lo spostamento meccanico minore Selezionare OFF per non abilitare o disabilitare questa opzione Option CMY SPEED Lets you select two different CMY movement speed Normal Fast Permette di selezionare una delle due differenti velocità di movimento dei filtri CMY Normal Fast Option DIMMER CURVE Lets you select four different Dimmer curves Dimmer curve 1 Dimmer curve 2 Dimmer curve...

Page 7: ...onano sempre in maniera constante e l uscita di luce rimane ridotta senza variazioni Constant Le ventole funzionano sempre al massimo regime Option SETTING Used to save 3 different settings of the items in the option menu and relevant submenus Default preset User preset 1 User preset 2 User Preset 3 Load preset X is used to recall a previously stored configuration Save to preset X is used to save ...

Page 8: ...LED on from construction to date Partial counter It counts the number of LED partial working hours from the last reset to date Press OK to reset the partial counter A confirmation message appears on the display Select Reset to confirm or Go Back to undo the operation Permette di visualizzare le ore di funzionamento totali e parziali dei LED Total counter Conta il numero di ore di funzionamento del...

Page 9: ...ion UID Shows the exclusive address of the fixture to use communicate via RDM Mostra l indirizzo esclusivo del dispositivo da utilizzare per comunicare via RDM MANUAL CONTROL Manual Control RESET It lets you reset the projector from the projector control panel Permette di eseguire il reset del proiettore dal pannello comandi del proiettore stesso Manual Control CHANNEL It lets you set the channel ...

Page 10: ...a group of fixtures Permette di eseguire tramite pannello comandi delle piccole regolazioni elettroniche degli effetti in modo tale da ottenere una migliore uniformità tra i proiettori Advanced MENU LOCKING It allows you to assign a password to lock the access to the ADVANCED menu to avoid any wrong setting or operation by people there are not from the technical staff The default Unlock Code is 12...