Clay Paky V.I.P. HTI 300 Instruction Manual Download Page 3

7

The products referred to in this manual comply with the European

Community Directives governing:

• Low voltage 73/23 

• Electromagnetic compatibility 89/336

WIRING DIAGRAMS

8

TECHNICAL DATA

7

ELECTRICAL/MECHANICAL 
CHARACTERISTICS

Power supply

V.I.P. HTI 300
• 220 - 240V 50Hz 
• 200V 50Hz - 230V 60Hz
• 200V 60Hz
• 120V 60Hz

V.I.P. 250 HAL
• 200 - 240V 50/60Hz 
• 100 - 120V 50/60Hz

S.I.P. 300 HAL
• MAX 240V 50/60Hz 

Lamps

• HTI 300W metal iodide

- Colour temperature 6500 K
- Luminous flux 20,000 lumen
- Fitting SFc 10-4
- Duration 750 h

• 24V 250W halogen

- Colour temperature 3450 K
- Luminous flux 9,000 lumen
- Fitting G6.35
- Duration 300 h

• M38 300W halogen 

- Colour temperature 2,900 K
- Luminous flux (120V) 5,500 lm
- Luminous flux (230V) 5,000 lm
- Fitting GY9.5 
- Duration 2000 h

Power uptake

• V.I.P. HTI 300 : 800VA (230V 50Hz)
• V.I.P. 250 HAL: 260VA (230V 50Hz)
• S.I.P. 300 HAL: 300VA (120V 60Hz)

OPTICAL SYSTEM

Optical unit
- Base in die-cast aluminium.
- Twin lens condenser.
- High output parabolic mirror.

Objectives

• Standard:  1:2,4/100 mm 
• Optional: 1:4/165 mm
• Optional: 1:2,8/85 mm three-lens
• Optional: 1:3,5/70÷120 mm zoom

CONSTRUCTION CHARACTERISTICS 

Safety devices

- Power switches off automatically in the

event of overheating (V.I.P. only).

- Power switches off when the cover is

opened (V.I.P. HTI 300 only).

- Short circuit protection on effects guides.

Cooling

Forced ventilation by means of axial flow
fans (V.I.P. only).

Housing

In extruded, die-cast aluminium, painted with
epoxy powder paint.

Support

- Steel mounting painted with epoxy powder

paint.

- Three installation positions 25 mm apart.
- Mounting adjustable through 120°.

Working position

- Works in any position.

Maintenance

- Easily accessible interior, thanks to large

size of opening cover.

Dimensions and weights

• V.I.P. HTI 300

- 210x480x130 mm 
- 7,1kg 

• V.I.P. 250 HAL 

- 210x480x130 mm 
- 6,8 kg

• S.I.P. 300 HAL 

- 210x360x130 mm 
- 2,0 kg

E

N

fuse

L

fuse

SW

FAN

230V

200V-60Hz

Bth60

480mA

PTC

24V

50/60Hz

20VA

IGNITOR

N

L

230V-50Hz

200V-50Hz

MSW

t

BALLAST

D

M

M

M

M

V.I.P. HTI 300

Bth60

480mA

PTC

E

N

fuse

L

fuse

FAN

SW

MSW

t

IGNITOR

50/60Hz

24V

20VA

120V

N

L

D

120V/60Hz

M

M

M

M

V.I.P. HTI 300 (120V 60Hz)

E

N

fuse

FAN

L

fuse

SW

24V-250W

LAMP. ALO.

PTC 480mA

TRAS.

D

C

A

B

Bth60

t

M

M

M

M

120V 50/60Hz

110V 50/60Hz

100V 50/60Hz

V.I.P. 100-120V

B

C

D

POS.

A

FIG.

V.I.P. 200-240V

TRAS.

001

220V 50/60Hz

240V 50/60Hz

230V 50/60Hz

002

200V 50/60Hz

TRAS.

M= Motor

V.I.P. 250W HALOGEN

E

N

L

LAMP. ALO.

M38-300W

S.I.P. 300W

REACTIVE MAINTENANCE

6

No mains electricity supply.

Check that power is available at the
mains socket and/or the conductivi-
ty of the fuses.

Lamp worn or faulty.

Change lamp.
(See instructions).

No voltage to effects guides.

Contact an authorised technician.

Effects motors don’t work.

Contact an authorised technician.

Lenses broken.

Contact an authorised technician.

Deposit of dust or grease.

Clean.
(See instructions).

Lens dirty.

Clean.
(See instructions).

MOTORISED EFFECTS NOT WORKING (V.I.P.)

PROJECTOR DOES NOT COME ON

PROJECTION FAULTY

FAULTS

REDUCED BRIGHTNESS

RINGS APPEAR AROUND PROJECTION

POSSIBLE CAUSES

CHECKS AND 

CORRECTIVE ACTION

The contents of this manual are not binding. In line with its strategy of constant product evolu-