32
ALPHA SPOT QWO 800 &
“
ST
”
• TILT FINE - channel 29
Operation with option Invert Tilt
G
Off
(Pan conventionally represented at 0 bit and option Invert Pan
G
Off)
BIT
255
0
S
E
TX
SEL
DM X
S
E
TX
SEL
DMX
Operation with option Invert Tilt
G
On
(Pan conventionally represented at 0 bit and option Invert Pan
G
Off)
• TILT - channel 28
Operation with option Invert Tilt
G
Off
(Pan conventionally represented at 0 bit and option Invert Pan
G
Off)
BIT
255
128
0
S
E
TX
SEL
DMX
S
E
TX
S EL
DMX
S
E
TX
SEL
DMX
Operation with option Invert Tilt
G
On
(Pan conventionally represented at 0 bit and option Invert Pan
G
Off)
BIT
255
128
0
S
E
TX
SEL
DMX
S
E
TX
SEL
DMX
S
E
TX
SEL
DMX
BIT
255
0
S
E
TX
SEL
DMX
S
E
TX
SEL
DMX
• PAN FINE - channel 27
Operation with option InvertPan
G
Off
(Tilt conventionally represented at 35 bit and option Invert Tilt
G
Off)
BIT
255
0
Operation with option InvertPan
G
On
(Tilt conventionally represented at 35 bit and option Invert Tilt
G
Off)
BIT
255
0
• FUNCTION - channel: 30
BIT
EFFECT
255
51-62
38-50
25-37
12-24
0-11
LINEAR (Default)
UNUSED RANGE
FREE
63
CONVENTIONAL
DIMMER CURVE
FUNCTION
FAST (Default)
NORMAL
PAN-TILT
FUNCTION
The functions are actived passing through the unused range and staying 5 seconds in
necessary level
• RESET - channel: 31
BIT
EFFECT
255
128
127
77
76
26
25
0
Complete reset is activated passing
throug the unused range and staying
5 seconds in complete reset levels.
COMPLETE RESET
PAN / TILT RESET
PAN / TILT RESET
EFFECTS RESET
EFFECTS RESET
UNUSED RANGE
Pan / Tilt reset is activated passing
throug the unused range and staying
5 seconds in Pan / Tilt reset levels.
Effects reset is activated passing
throug the unused range and staying
5 seconds in Effects reset levels.
COMPLETE RESET
The functions are actived passing through the unused range and staying 5 seconds in
necessary level