Clavia Nord Drum 3P User Manual Download Page 19

FCC Information (U.S.A.)

1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!

This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications 

not expressly approved by Clavia may void your authority, granted by the FCC, to use the product.

2. IMPORTANT:

 When connecting this product to accessories and/ or another product use only high quality shielded cables. 

Cable/s supplied with this product MUST be used. Follow all installation instructions. Failure to follow instructions could void 

your FCC authorization to use this product in the USA.

3. Note: 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of 

the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa-

tion. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with 

the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will 

not occur in a particular installation. If this equipment is found to be the source of interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or 

more of the following measures:
 

– Reorient or relocate the receiving antenna.

 

– Increase the separation between the equipment and receiver.

 

– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

 

– Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

Unauthorized changes or modification to this system can void the users authority to operate this equipment.
This equipment requires shielded interface cables in order to meet FCC class B Limit.

           For 

Canada

NOTICE

This Class B - digital apparatus complies with Canadian ICES-003.

AVIS

Cet appareil numérique de la classe B - est conforme à la norme NMB-003 du Canada.

DECLARATION OF CONFORMITY 

Compliance Information Statement

 

 

Model Name: Nord Drum 3P

 

 

Type of Equipment: Digital drum unit

 

 

Responsible Party: Clavia DMI AB

 

 

Address: P.O. BOX 4214. SE-102 65 Stockholm Sweden

 

 

Telephone: +46-8-442 73 60

Summary of Contents for Nord Drum 3P

Page 1: ...Nord Electro 5 User Manual OS v1 X 1 User Manual English Nord Drum 3P OS Version 1 x Edition C Part No 50432 Copyright Clavia DMI AB Edition C...

Page 2: ...ped The lightning flash with the arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated voltage within the products en closure that may be of suff...

Page 3: ...pe 7 Freq 8 Dyn Filter 8 Decay 8 Mode 8 Tone Parameters 8 Spectra 8 Wave 8 Freq 9 Dyn Filter 9 Decay 9 Mode 9 Bend 9 Time 9 Pitch 9 Scl Pre 9 Click Parameters 10 Level 10 Type 10 Mix Parameters 10 Noi...

Page 4: ...or highest value Certain parameters have a default setting in the middle between the highest and lowest settings Bend is one example with 0 Bend in the middle of the range When turning the Dial the s...

Page 5: ...m Kit Store or Drum Store operation TRIG TAP BPM BUTTON Use the TRIG TAP BPM button to trigger the sound of the currently selected Channel This button can also be used to enter a tempo by tapping it w...

Page 6: ...s the Drum banks and use the Dial to browse through them The selected sound will replace the content of the currently active Channel Value Description bd Bass drums Sn Snare drums to Toms HH Hi hats C...

Page 7: ...t a Lower Parameter written on the sec ond row above a parameter button and indicated by a red label hold down the LOWER PARAM button while operating the Dial Another method for accessing the Lower Pa...

Page 8: ...o the force with which the pad is triggered The diagrams below show how the Decay and Dynam ic Decay mode parameters interact at different settings Range E E2 E3 Exponential L Linear Gate 0 50 TONE PA...

Page 9: ...lter is not available if the A 1 sine waveform is select ed Range 0 9 DECAY The DECAY parameter sets the length of the Tone The higher the value the longer the sound Range 0 50 MODE Decay MODE determi...

Page 10: ...hort pulses C1 3 Clicks with a pitched and somewhat chirpy char acter Range n1 3 P1 3 H1 3 C1 3 MIX PARAMETERS NOISE LVL NOISE LVL sets the volume of the Noise Part Range 0 50 TONE LVL TONE LVL sets t...

Page 11: ...instead Range 60 179 90 179 90 300 0 050 0 001 s TAP BPM When in BPM mode the tempo can be entered by tapping the TRIG TAP BPM button A minimum of four taps are required for defining the tempo indica...

Page 12: ...function to create backups of individual Drum Kits or for sharing with other Nord Drum 3P users Start the transmission by pressing DRUM KIT SELECT M M Any edits made to the currently selected Drum Kit...

Page 13: ...alues will be stored in the Nord Drum 3P even after disconnecting the Kick pedal or turning off the machine Range 1 20 INIT SOUND Press SHIFT and hold down the two INIT SOUND buttons to reset a Channe...

Page 14: ...DI Messages and change the noise filter on that channel M M If you want to make parameter changes on more than one Nord Drum 3P channel at the same time using overdub re cording techniques the Individ...

Page 15: ...nsfer entire Drum Kit banks to or from the Nord Drum 3P use the Nord Drum 3P Manager application See page 15 for details THE NORD BEAT APP Nord Beat is a free sequencer application for the iPad design...

Page 16: ...ters The MIDI In put is also used when you update the unit with new operating systems MIDI OUT Connect the MIDI Output to a computer or sequencer to record what is being played on the pads The perform...

Page 17: ...mmand A retrieved bank will contain all the 50 Drum Kits and will be saved on the computer hard drive as a nd3_kitbank file SEND DRUM KIT BANKS Use the KIT Send Bank command select a nd3_kitbank file...

Page 18: ...7 Low pass filter 7 M Master Level 5 Memory Protect 6 11 MIDI 12 MIDI Channels 12 MIDI Controller 14 MIDI In 16 MIDI Note 12 MIDI Out 16 Mode Noise Decay 8 Mode Tone Decay 9 Mono Group 7 N Noise 7 Noi...

Page 19: ...d to be the source of interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more...

Page 20: ......

Reviews: