Wiring diagram 

HE7420

 

HE7402

 

HE8407 optional control switch

 

Both of these units are suitable for re-
mote control operation, with the use of 
remote control switch part no. HE8407 
shown in the diagram below 
 

NOTE: The unit MUST be reliably earthed

Operation

 

The right hand switch connects the mains supply to the fan motor 
(giving a cool airflow) and energises the heat control switches. 
 

Heat control HE7402

 

HE7402

 

When  the  centre  switch  (marked  with  a  single  black  dot)  is 
pressed  the  heat  output  is  1kW.    When  the  left-hand  switch 
(marked  with  two  black  dots)  is  pressed  the  heat  output  is  2kW.  
When both switches are pressed the heat output is 3kW. 
 

Heat control HE7420

 

When  the  centre  switch  (marked  with  a  single  black  dot)  is 
pressed  the  heat  output  is  1.5kW.    When  the  left-hand  switch 
(marked  with  two  black  dots)  is  pressed  the  heat  output  is  3kW.  
When both switches are pressed the heat output is 4.5kW. 

To replace a switch

 

1. 

Remove the top cover. 

2. 

Release the three fixings which secure the switch brack-
et to the right hand side of the main case. 

3. 

Remove the push-on connectors, noting their position. 

4. 

Remove by compressing the plastic retaining tabs, and 
lifting out the switch. 

5. 

Insert  the  new  switch,  refit  and  push  on  connectors  in 
the correct order, test and reassemble. 

To replace the fan heater assembly

 

1. 

Remove the top cover. 

2. 

Disconnect  the  internal  wiring  from  the  main  terminal 
block and earth stud. 

3. 

Release the three fixings which secure the switch brack-
et to the right hand of the main case. 

4. 

Remove the four nuts and washers fixing the fan heater 
assembly to the back of the case. 

5. 

The  fan  heater  assembly  can  now  be  eased  forward 
and removed from the heater case. 

6. 

Fit  replacement  fan  heater  and  reassemble  in  reverse 
order. 

Spares 

It  is  essential  when  ordering  spares  or  replacement  parts  to 
state  the  model  number  and  the  serial  number  on  the  rating 
place fixed to the top of the unit. 
 
In  the  interest  of  progress  the  Company  reserve  the  right  to 
vary specifications from time to time without notice.  The mate-
rial listed is offered subject to the Company’s General Condi-
tions of Sale, a copy of which can be obtained on request. 
 

NOTE:  DO NOT COVER any of the air inlet or outlet grills, at any 
time.

 

This optional control switch is useful if you have the unit mounted up 
high, as you would need a step ladder to reach the switches.  You 
can fit this switch lower down, allowing you to easily change the 
heat settings.

 