![Claudgen HE7402 Installation & Operation Manual Download Page 4](http://html1.mh-extra.com/html/claudgen/he7402/he7402_installation-and-operation-manual_2619470004.webp)
41000971 Iss 08
4
C
USTOMER
H
ELPLINE
Should you need any advice on the use of your new Consort product please contact our Helpline:
Consort Equipment Products Limited
Thornton Industrial Estate, Milford Haven, Pembrokeshire, SA73 2RT
Tel: 01646 692172 Fax: 01646 695195 Email: [email protected] Web: www.consortepl.com
Operation hours: Mon to Thu 8.30am to 4.30pm | Fri 8.30am to 3.30pm
BS EN ISO 9001 Registered Company No FM12671
Wiring diagram
HE7420
HE7402
HE8407 optional control switch
Both of these units are suitable for re-
mote control operation, with the use of
remote control switch part no. HE8407
shown in the diagram below
NOTE: The unit MUST be reliably earthed.
Operation
The right hand switch connects the mains supply to the fan motor
(giving a cool airflow) and energises the heat control switches.
Heat control HE7402
HE7402
When the centre switch (marked with a single black dot) is
pressed the heat output is 1kW. When the left-hand switch
(marked with two black dots) is pressed the heat output is 2kW.
When both switches are pressed the heat output is 3kW.
Heat control HE7420
When the centre switch (marked with a single black dot) is
pressed the heat output is 1.5kW. When the left-hand switch
(marked with two black dots) is pressed the heat output is 3kW.
When both switches are pressed the heat output is 4.5kW.
To replace a switch
1.
Remove the top cover.
2.
Release the three fixings which secure the switch brack-
et to the right hand side of the main case.
3.
Remove the push-on connectors, noting their position.
4.
Remove by compressing the plastic retaining tabs, and
lifting out the switch.
5.
Insert the new switch, refit and push on connectors in
the correct order, test and reassemble.
To replace the fan heater assembly
1.
Remove the top cover.
2.
Disconnect the internal wiring from the main terminal
block and earth stud.
3.
Release the three fixings which secure the switch brack-
et to the right hand of the main case.
4.
Remove the four nuts and washers fixing the fan heater
assembly to the back of the case.
5.
The fan heater assembly can now be eased forward
and removed from the heater case.
6.
Fit replacement fan heater and reassemble in reverse
order.
Spares
It is essential when ordering spares or replacement parts to
state the model number and the serial number on the rating
place fixed to the top of the unit.
In the interest of progress the Company reserve the right to
vary specifications from time to time without notice. The mate-
rial listed is offered subject to the Company’s General Condi-
tions of Sale, a copy of which can be obtained on request.
NOTE: DO NOT COVER any of the air inlet or outlet grills, at any
time.
This optional control switch is useful if you have the unit mounted up
high, as you would need a step ladder to reach the switches. You
can fit this switch lower down, allowing you to easily change the
heat settings.