Claudgen HE7230SL Installation And Operating Manual Download Page 5

 

5.1  SL models 

 

The heaters HE7230SL, HE7245SL and HE7260SL can be controlled by CONSORT CRXSL or any 

SL  wireless  controller.  Each  CRXSL  or  SL  controller  can  control  any  number  of  heaters  providing 

they are in the RF range. For more details please follow the instructions supplied with the controller. 

5. Operation. 

4. Electrical Connections. 

4.2 Electrical connections for SL and RX models

 

Fig.8 Heater with terminal cover open

 

Fig.9 Terminal cover detail

 

41001475 Iss 03 

5.2  RX Models  

 

The  heaters  HE7230RX,  HE7245RX  and  HE7260RX  can  be  controlled  by  CONSORT  wireless 

controller  CRXSL.  The  heaters  will  not  work  without  a  controller.  Each  controller  has  unique 

identification  code,  it  can  control  an  unlimited  number  of  heaters  in  the  same  room  and  will  not 

interfere  with  other  controllers  within  the  building.  For  more  details  please  follow  the  instructions 

supplied with the controller. 

SLPB 

SLVTB 

CONSORT CRXSL and SL Controllers 

SLVT 

CRXSL 

CONSORT Wireless controller CRXSL 

Summary of Contents for HE7230SL

Page 1: ...tails 3 Electrical Connections 4 Operation 5 Servicing Maintenance 6 41001475 Iss 03 Recessed Ceiling Heaters Catalogue Numbers HE7230SL HE7245SL HE7260SL HE7230RX HE7245RX HE7260RX Installation and O...

Page 2: ...d that the electrical supply to the base unit in the heater is via an appropri ate switched isolator in accordance with the regulations in force in the country of use and must be via a fused isolator...

Page 3: ...r ance allows for cable entry and prevents combustible surfaces overheating The minimum mounting height floor to grille is 2 2m for the HE7230SL RX 1 General Information HE7245SL RX and 2 5m for the H...

Page 4: ...om vibration The discharge grille and diffuser assembly can now be fitted into the ceiling frame 4 1 Electrical Connections These units are suitable for connection to a 230 240 Volt 50 Hz single phase...

Page 5: ...Fig 8 Heater with terminal cover open Fig 9 Terminal cover detail 41001475 Iss 03 5 2 RX Models The heaters HE7230RX HE7245RX and HE7260RX can be controlled by CONSORT wireless controller CRXSL The he...

Page 6: ...uction of the free airflow by thermal cut outs If this happens the thermal cut outs switch off the appliance The ap pliance will not operate until the heater is discon nected from the mains supply and...

Page 7: ...7...

Page 8: ...contact our Helpline Consort Equipment Products Limited Thornton Industrial Estate Milford Haven Pembrokeshire SA73 2RT Tel 01646 692172 Fax 01646 695195 Email technical consortepl com Web www consort...

Reviews: