background image

 

INDEX

                                                                                            

Section

 

 

General information ------------------------------------------------------------ 1 

Dimensions  ---------------------------------------------------------------------- 2 

Installation Details -------------------------------------------------------------- 3 

Electrical Connections  -------------------------------------------------------- 4 

Operation ------------------------------------------------------------------------- 5 

Servicing & Maintenance ----------------------------------------------------- 6 

41001456 Iss 01 

R

ECESSED

 W

ARM

 C

EILING

  

H

EATERS

 

 

C

ATALOGUE

 N

UMBERS

  

HE7230, HE7245, HE7260, 
HE7230RX, HE7245RX, HE7260RX 
 

I

NSTALLATION

 

AND

 O

PERATING

 M

ANUAL

 

Consort Equipment Products Limited 

Thornton Industrial Estate, Milford Haven 

Pembrokeshire, SA73 2RT 

Tel: 01646 692172 Fax: 01646 695195 

Mon to Fri 8.30 am to 3.30 pm 

Email: [email protected]        Web: www.consortepl.com 

Summary of Contents for HE7230

Page 1: ...01 RECESSED WARM CEILING HEATERS CATALOGUE NUMBERS HE7230 HE7245 HE7260 HE7230RX HE7245RX HE7260RX INSTALLATION AND OPERATING MANUAL Consort Equipment Products Limited Thornton Industrial Estate Milford Haven Pembrokeshire SA73 2RT Tel 01646 692172 Fax 01646 695195 Mon to Fri 8 30 am to 3 30 pm Email enquiries consortepl com Web www consortepl com ...

Page 2: ... the installer should ensure that a suitable isolating switch is connected in the mains supply 1 4 Controller RX models The HE7230RX HE7245RX HE7260RX heaters are supplied without a controller The RX models will not work without the controller See section 5 1 for more details 1 5 Controller standard models The HE7230 HE7245 HE7260 heaters are sup plied with a remote controller The remote control u...

Page 3: ...ation Sole liability rests with the installer to ensure that protective safety wear such as hand eye ear and head protection is used during installation of the product 1 General Information Do not rest anything especially ladders against the product 1 10 Standards Units conform to the European electrical standard BS EN 60335 2 30 2 Dimensions 41001456 Iss 01 ...

Page 4: ...s free from vi bration The discharge grille and diffuser assem bly can now be fitted into the ceiling frame 4 1 Electrical Connections These units are suitable for connection to a 230 240 Volt 50 Hz single phase supply The appliance shall be connected to the supply via an appropriate switched fused double pole isolator having a contact separation of greater than 3mm Test for correct operation and ...

Page 5: ...switch supplied eg BMS then the heat output can be selected by connecting the appropriate terminals WIRED TERMINALS HE7230 HE7245 HE7260 H1 H2 F 3000W 4500W 6000W H1 F 1000W 1500W 2000W H2 F 2000W 3000W 4000W Please note the F terminal must always be connected F Fan H1 Heating element 1 H2 Heating element N Neutral E Earth 41001456 Iss 01 Fig 5 Remote switch terminal side view Fig 4 Mains supply d...

Page 6: ...The thermostat should be wired between the isolator switch and the heater remote switch For HE7245 HE7260 or to control more than one HE7230 heaters by a thermostat a contactor or a relay in conjunction with the thermostat should be used 5 Operation 4 Electrical Connections 4 4 Electrical connections for wireless control models Fig 8 Heater with terminal cover open Fig 9 Terminal cover detail To s...

Page 7: ...Thermal cut out The units are protected from overheating in the event of fan failure or an obstruction of the free airflow by thermal cut outs If this happens the thermal cut outs switch off the appliance The ap pliance will not operate until the heater is discon nected from the mains supply and it has cooled down If this fault re occurs again refer to the section 6 4 fault finding 6 Servicing Mai...

Page 8: ...8 ...

Reviews: