Revised: March 9, 2020
Page 6
Press and hold the calibration button with the LED indicating
g
until the
g
starts alternating with
E
.
The gauge
empty
indication will now be set.
Press and hold the calibration button to change the fuel gauge’s pointer position. The first time the
button is pressed and held, the fuel level shown on the gauge will decrease (
or in some cases
increase
). The next time the button is pressed and held, the fuel level shown on the gauge will
change in the opposite direction. The direction the fuel level indicator changes will alternate between
increasing and decreasing every time it is pressed and held.
Once the fuel gauge is indicating
empty
, wait 8 seconds without pushing the calibration button to
save the calibration. The LED display will change back to
g
to confirm calibration is saved.
Press and hold the calibration button with the LED indicating
g
until the
g
starts alternating with
2
.
The gauge
1/4
tank indication will now be set.
Press and hold the calibration button to change the fuel gauge’s pointer position. The first time the
button is pressed and held, the fuel level shown on the gauge will decrease (
or in some cases
increase
). The next time the button is pressed and held, the fuel level shown on the gauge will
change in the opposite direction. The direction the fuel level indicator changes will alternate between
increasing and decreasing every time it is pressed and held.
Once the fuel gauge is indicating
1/4
, wait 8 seconds without pushing the calibration button to save
the calibration. The LED display will change back to
g
to confirm calibration is saved.
Press and hold the calibration button with the LED indicating
g
until the
g
starts alternating with
5
.
The gauge
1/2
tank indication will now be set.
Press and hold the calibration button to change the fuel gauge’s pointer position. The first time the
button is pressed and held, the fuel level shown on the gauge will decrease (
or in some cases
increase
). The next time the button is pressed and held, the fuel level shown on the gauge will
change in the opposite direction. The direction the fuel level indicator changes will alternate between
increasing and decreasing every time it is pressed and held.
Once the fuel gauge is indicating
1/2,
wait 8 seconds without pushing the calibration button to save
the calibration. The LED display will change back to
g
to confirm calibration is saved.
Press and hold the calibration button with the LED indicating
g
until the
g
starts alternating with
7
.
The gauge
3/4
tank indication will now be set.
Press and hold the calibration button to change the fuel gauge’s pointer position. The first time the
button is pressed and held, the fuel level shown on the gauge will decrease (
or in some cases
increase
). The next time the button is pressed and held, the fuel level shown on the gauge will
change in the opposite direction. The direction the fuel level indicator changes will alternate between
increasing and decreasing every time it is pressed and held.
Once the fuel gauge is indicating
3/4
, wait 8 seconds without pushing the calibration button to save
the calibration. The LED display will change back to
g
to confirm calibration is saved.
Press and hold the calibration button with the LED indicating
g
until the
g
starts alternating with
F
.
The gauge
full
tank indication will now be set.
Press and hold the calibration button to change the fuel gauge’s pointer position. The first time the
button is pressed and held, the fuel level shown on the gauge will decrease (
or in some cases
increase
). The next time the button is pressed and held, the fuel level shown on the gauge will
change in the opposite direction. The direction the fuel level indicator changes will alternate between
increasing and decreasing every time it is pressed and held.
Once the fuel gauge is indicating
full
, wait 8 seconds without pushing the calibration button to save
the calibration. The LED display will change to
C
to confirm calibration is saved.
Press and hold the calibration button with the LED indicating
C
to exit calibration mode.