Protection Modes and Indicators
The front LED shows the status of the amplifier. When starting up normally, the CAV500 will show a FLASHING
RED LED for about 15 seconds and if all is normal, the LED will go SOLID RED. If there is a fault, the LED will
go to a FLASHING GREEN LED. The CAV500 is equipped, except for some early production models, with ten
Mosfet protection fuses. In the event that one or more of these fuses would blow, the technician will first need
to identify and cure the cause of failure (please report to troubleshooting guide). When the cause has been
identified, disconnect the unit from the system including the AC power. Remove the top cover and look for
damaged or burned components. If no other components than the fuses appear to be damaged, the
technician can then replace the broken fuses with the same value and rating (please report to fuses section).
The Mosfet fuses are located on the control board. When replacing fuses, please make sure that the fuse
holder are holding the fuses very tightly. A loose fuse holder can translate into distortion on top of the signal.
Summary of Contents for CAV-500
Page 4: ...PRO SVR_LEGACY Page 4 of 13 Block diagrams...
Page 14: ......
Page 15: ......
Page 16: ...B1D2XR01_N sch 1 Thu Jul 26 16 39 02 2007...
Page 17: ...B1D3XR02 sch 1 Thu Jul 26 16 27 07 2007...
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ...B1D6XR01 sch 1 Thu Jul 26 16 35 18 2007...
Page 24: ......
Page 25: ......
Page 26: ...B1D9XR02 sch 1 Thu Jul 26 16 25 14 2007...
Page 27: ......