PE 6001
MOVABLE ELECTRO HYDRAULIC LIFT
PE 8000M
BODY REPAIR LIFT TABLE MONO CYLINDER WITH
MECHANIC LOCK 3T
36
ADD OIL AND CHECK THE CONTROL PHASE:
After installing the lifting table and connecting the hydraulic system, electrical system and gas
loop, operate it as follows:
• Open the hydraulic oil tank, add 12L of «20#» hydraulic oil into the oil tank, the hydraulic oil is
provided by the user.
Make sure the hydraulic oil is clean, to avoid any impurity in the oil line, drive the digester of
the oil line and do not operate the solenoid valve.
Only qualifi ed personnel are allowed to carry out the operations.
• All bearings and hinges of this machine must be lubricated once a week with a grease gun.
• The upper and lower sliding blocks and other moving parts must be lubricated once a month.
• The hydraulic oil must be changed once a year. The oil level should always be kept at the
upper limit position.
The machine should be lowered to the lowest position when replacing the hydraulic oil,
the old oil should be allowed to drain out, and the hydraulic oil should be fi ltered.
• Each team checks the agility and reliability of the pneumatic safety equipment.
TROUBLESHOOTING