![CLAS AC 5300 Manual Download Page 10](http://html1.mh-extra.com/html/clas/ac-5300/ac-5300_manual_2616390010.webp)
AC 5300
GLOW PLUG ANALYZER
The glow plugs can now be tested accurately.
Disconnect the voltage supply from the glow plug on the vehicle.
Connect the black alligator clip to the vehicle earth.
Turn the analyser on by pushing and releasing the glow plug button.
Touch the "positive" end of the glow plug with the tip of the red test probe.
The AC 5300 will take a reading every few seconds and the results are displayed on the
LCD as follows:
LCD Display
Parameters
Indication
Beep Alarm
0.00 to 0.06
Ω
Shorted
(cont. beep
x20)
0.07 to 2.50
Ω
OK
(no sound)
2.51 to 5.5
Ω
High resis-
tance
(2 beeps x 5)
5.51 to 25.0
Ω
Bad resistance (cont. beep
x20)
Open or 25.0
Ω
above
Open Circuit
(cont. beep
x20)
Low Battery warning
Cut OFF at 2.0 V