12
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
TROUBLESHOOTING
Problem
Check
Solution
Motor stops and
will not run.
1. Overload switch has tripped
due to excessive load on
the chuck.
2. Defective/broken switch.
2. Damaged power cable.
3. Open circuit, loose
connections or burned out
motor.
4. Blown fuse or circuit breaker.
5. Low voltage.
Switch off the machine and
wait for the components to
cool down and the overload
to re-set. Then turn the lathe
back on and press the re-set
button to re-start.
Send to your Clarke dealer for
repair.
Send to your Clarke dealer for
replacement.
Replace fuse or re-set circuit
breaker. Turn off other
machines on same circuit.
Check the power supply for
correct voltage. Use another
circuit or have a qualified
electrician upgrade the
power supply.
Motor will not start
and fuses or circuit
breaker trip out.
1 Short circuit in motor or
power cable.
2. Incorrect fuses or circuit
breakers.
Send to your Clarke dealer for
repair.
Replace with correct fuse or
circuit breaker for the circuit.
Motor fails to
reach full power.
1. Overloaded circuit.
2. Unsuitable extension cable
Turn off other machines &
retry.
Replace with correct size
extension cable.
Motor stalls.
1. Short circuit in motor.
2. Incorrect fuses or circuit
breakers.
3. Overloaded circuit.
4. Low voltage.
Send to your Clarke dealer for
repair.
Replace with correct fuse or
circuit breaker for the circuit.
Turn off other machines & retry
Check the power supply for
correct voltage. Use another
circuit or have a qualified
electrician upgrade the
service.
Noisy operation
1. Incorrect belt tension.
2. Dry spindle.
3. Loose drive pulley.
Adjust belt tension. See
Replacing the Belt on page 11
Lubricate the spindle.
Tighten the retaining set-
screw on the pulley.
Summary of Contents for WOODWORKER CWL325V