Clarke TAM101 Operating & Maintenance Instructions Download Page 3

ELECTRICAL CONNECTIONS

WARNING: THIS MACHINE MUST BE EARTHED.

I

nstallation should be carried out by a qualified electrician in accordance with

I.E.E. Regulations. However, in the further interests of safety we would emphasize
the following :-

This pump should be connected to a standard domestic 13 amp, 230 volt (50Hz),
electrical supply and we strongly recommend that the connection be made via
a Residual Current Device (RCD).

IMPORTANT: 

Should the supply be taken from a normal 13 amp socket, then the

plug used must be to BS 1363 standard, and the wires should be wired up in
accordance with the following colour code:

Green & Yellow .......... Earth or marked with a letter “E” or Earth symbol  “     ”.

Blue ............................. Neutral or terminal marked with a letter “N”

Brown .......................... Live or terminal marked with a letter “L”

FUSE RATING

The fuse in the plug must be rated at

  5 amps

3

T

he pump MUST be wired according to the diagram below, and ensuring the

following precautions are strictly observed:

1.

The cable used must be of sufficient size
to ensure it is a tight fit in the cable gland.

2.

Ensure the cable gland is correctly used.
The clamp must firmly clamp the outer
cable sheath and NOT the conductors.

3.

Ensure the earth conductor is correctly
connected to the earth terminal.

The bare conductor should be wrapped
around the body of the screw, positioned
between the two washers, and the screw
suitably tightened.

WARNING:

DO NOT attempt electrical installation work if you are in any doubt as to how it

should be properly carried out. Consult a qualified electrician.

ACCESSORIES

1” Foot Valve Filter

7950561

1”  BSP Spigot Hose Connector

7950210

1” I.D. Reinforced Hose for suction and delivery.

7955010

1” I.D. Layflat Hose for delivery only.

7955110

PARTS & SERVICE

When disposing of this product, do not dispose of with general waste. It must be disposed of according to the laws
governing Waste Electrical and Electronic equipment, at a recognised disposal facility.

SPECIFICATIONS

TAM101

CEB102

Motor

230V 50Hz 1ph

230V 50Hz 1ph

Power

0.5HP (370W)

0.5HP (370W)

Speed

2850 RPM

2850 RPM

Max. Head

35M

35M

Max. Lift (Suction)

8M

8M

Bore Size

1”BSP

1”BSP

Max. Output

35 litres/min

35 litres/min

Weight

5.8kg

6.25kg

Part Number

7320375

7230325

Please note that the details and specifications contained herein, are correct at the time of going to
print. However, CLARKE International reserve the right to change specifications at any time without prior
notice. Always consult the pump’s data plate

Please contact your nearest dealer, or

CLARKE International, on one of the following numbers.

PARTS & SERVICE TEL:  020 8988 7400

PARTS & SERVICE FAX:  020 8558 3622

or    e-mail as follows:

PARTS:   [email protected]

SERVICE:    [email protected]

PARTS & SERVICE

6

Reviews: