Clarke psp125b Operation & Maintenance Instructions Manual Download Page 6

6

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

MANUAL OPERATION

The pump can also be switched on 
manually by inserting the sensor into 
the socket on the side of the pump.

NOTE: If the sensor is inserted into the 

socket, the pump will run 
continuously. 

NOTE:

Do not allow the pump to run 
dry.

POSITIONING THE PUMP

1. Place the pump on a flat surface in the area that you want to drain. 

• If there is sediment in the operating area, the pump should be placed 

vertically on house bricks, or similar.

• ALWAYS raise and lower the pump using a rope attached to the lifting 

handle.

• Take all necessary precautions as described on page 3. 

USING THE PUMP

1. Connect the mains plug to the mains supply.

• Always use a high sensitivity residual current device (RCD) which has a 

tripping current of less then 30mA.

2. Switch the mains power supply on.

• The pump will begin to drain water.

3. When pumping is finished, disconnect the pump from the mains power 

supply.

IMPORTANT: Do not allow the pump to run dry

WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE 
PUMP IF IT IS DAMAGED IN ANY WAY.

Summary of Contents for psp125b

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0216 400W PUDDLE PUMP WITH AUTO SENSOR MODEL NO PSP125B PART NO 7230694...

Page 2: ...hich it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONME...

Page 3: ...incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump explosive fl...

Page 4: ...t be connected to the terminal which is marked N or coloured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the...

Page 5: ...step hose adaptor can be screwed onto the elbow if required 1 Fit the supplied non return valve between the adaptor and the elbow 2 Trim the adaptor to the required size 3 Connect your hose not suppli...

Page 6: ...he operating area the pump should be placed vertically on house bricks or similar ALWAYS raise and lower the pump using a rope attached to the lifting handle Take all necessary precautions as describe...

Page 7: ...ntee Repairs must be carried out by your CLARKE dealer or contact the CLARKE Service Department on 020 8988 7400 STORAGE When the pump is not being used for extended periods clean and dry it thoroughl...

Page 8: ...ry using the pump in manual operation mode 7 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the...

Page 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS LIST DIAGRAM...

Page 10: ...sing 28 Stator 9 1 Nylon Secure Pressing Cap 29 Bush 9 2 Screw 30 Gasket 9 3 Rubber Clip 31 O ring 9 4 Ribbon 32 Aluminium Bushing 10 Clip 33 O ring 10 1 Clip 34 Front Cover 11 Self Tapping Screw 35 O...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 12: ......