![Clarke PSE1A Operation & Maintenance Instructions Manual Download Page 10](http://html1.mh-extra.com/html/clarke/pse1a/pse1a_operation-and-maintenance-instructions-manual_2616171010.webp)
10
CLEANING AND MAINTENANCE
WARNING!
MAKE SURE THAT THE PUMP IS DISCONNECTED FROM THE MAINS SUPPLY
BEFORE CLEANING, OR PERFORMING ANY MAINTENANCE.
•
These pumps should require no maintenance other than regular cleaning. If the
pump starts to show signs of wear or damage, contact your CLARKE dealer for
advice.
•
Do not attempt to repair the pump yourself, repairs must be carried out by your
CLARKE dealer, or contact the CLARKE Service Department, on 020 8988 7400.
•
Check the pump regularly to ensure the base is clear of leaves or other debris.
Replacing the Impeller
1
Remove the 3 screws on the base of the
pump, and remove the cover.
2
Use a small flat headed screwdriver to
remove the circlip.
3
Pull the old impeller off of the shaft.
4
Replace with a new impeller and lock it in
place using the circlip.
5
Replace the base and use the 3 screws to
secure.