Clarke Power Wash EHD130 Operating & Maintenance Instructions Download Page 8

  SHUTTING DOWN THE MACHINE

If the chemical injection facility has been used, disconnect the plastic tube from the
pick-up, and turn the pressure adjuster on the lance to HIGH pressure. Allow the pump to
run for a short while to cleanse the hose and lance, then switch OFF the pump.

Switch OFF at the mains electrical supply, and turn OFF the water supply -
disconnect where appropriate.

IMPORTANT: Operate

 the lance trigger once more to ensure there is no pressure in

the high pressure hose.

NEVER disconnect the high pressure hose unless you have operated the trigger.

  AFTER EACH USE

When using chemical detergents,
always ensure the system is
thoroughly flushed out after use as
described previously.

Ensure the hoses and power cable
are coiled and properly stowed. DO
NOT allow them to be left casually, in
a heap. This invites damage and will
cause rapid deterioration.

STORAGE

Store the Washer in an horizontal position, preferably under cover, protected from
the elements.
If there is a danger of freezing, the pump should be filled with antifreeze by inserting
the inlet and outlet hoses into a bucket of antifreeze as shown in the diagram,
start the machine and allow the antifreeze to circulate. After a short time stop the
machine using the procedure outlined on page 6, and store the machine with
the antifreeze still within the pump body.

NOTE

:

If you experience difficulty in starting the motor following a long period of storage,
it is possible that the seals within the pump have dried out and are gripping the
pistons. This problem may be alleviated by storing the machine with antifreeze
within the pump body, as described above.

MAINTENANCE

WARNING: Ensure the plug is removed from the socket before carrying out any

adjustment, servicing or maintenance.

Fig.8

8

Summary of Contents for Power Wash EHD130

Page 1: ...POWER WASHER MODELS EHD 130 160 170 OPERATING MAINTENANCE INSTRUCTIONS 0205 PART Nos 7330560 7330565 7330570 POWER WASHER MODELS EHD 130 160 170...

Page 2: ...E This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the produc...

Page 3: ...n water to the water inlet 8 Use only chemical cleaning agents detergents approved for power washing when using the chemical injection facility 9 Never use the chemical injection facility to introduce...

Page 4: ...3 PHASE supply preferably via a Residual Circuit Breaker RCB IMPORTANT The wires in the mains lead should be wired up in accordance with the following colour code Connect GREEN YELLOW coloured cord t...

Page 5: ...tlet that is to the left front of the machine looking from the front see Fig 2 The lance is in two sections assemble by screwing the two halves together A 3 4 BSP adapter with a 1 2 hose connector is...

Page 6: ...he OFF position The ON OFF switch is mounted on the top panel Turn the water tap fully on Start according to the following procedure a In order to ease the starting process and to prevent the possibil...

Page 7: ...etergent will be drawn up into the water flow NOTE Water pressure is regulated by turning the adjuster handle located in the middle of the lance and which doubles as a hand grip ANTICLOCKWISE to INCRE...

Page 8: ...t casually in a heap This invites damage and will cause rapid deterioration STORAGE Store the Washer in an horizontal position preferably under cover protected from the elements If there is a danger o...

Page 9: ...or detergent flow regulator not correctly set Bleed the system by quickly operating trigger several times If necessary operate the machine briefly without the high pressure hose connected Renew nozzle...

Page 10: ...30 Strain Relief FP19106100 31 Nylon Lock Nut FP19106200 32 Support Plate FP73132800A 33 Switch Assy FPEHD033 34 Cover FPEHD034 35 Contactor FPEHD035 36 Box FPEHD036 37 Seal FPEHD037 38 Motor FPEHD038...

Page 11: ...PARTS DIAGRAM 11...

Page 12: ...lug FP18107100 6 Bracket RH FP73132600 7 Screw FP10501700 8 Reel Locating Assy FP7303300 9 Outlet Connector FP73132900 10 Nut FP73042400 11 O Ring FP15103000 12 Washer FP15023500 13 O Ring FP13300900...

Page 13: ...n Wax 5 litre 3050815 Sand for use with Water Sand Blaster 7320005 SPECIFICATIONS EHD130 EHD160 EHD170 Motor 230V 50hz 1Phase 400V 50hz 3 Phase 400V 50hz 3 Phase Power Rating 2 7kW 5kW 5 5kW Fuse Rati...

Page 14: ...14...

Reviews: