![Clarke PG2500 Operation & Maintenance Instructions Manual Download Page 16](http://html1.mh-extra.com/html/clarke/pg2500/pg2500_operation-and-maintenance-instructions-manual_2615013016.webp)
16
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
CHECKING THE AIR FILTER
1. Unclip and remove the air filter
cover.
2. Remove the air filter element.
3. Make sure that the air filter is
clean and not damaged.
• If the air filter is damaged
contact Clarke spare parts
department for a replacement.
• If the filter is dirty, wash in a
solution of warm water and
mild detergent and rinse
thoroughly. Leave the filter to
dry completely, once it is dry immerse in clean engine oil and
squeeze to remove excess oil.
4. Replace the filter to its original position and replace the air filter cover.
CAUTION: DO NOT USE THE GENERATOR WITHOUT THE AIR FILTER FITTED,
THIS CAN DAMAGE THE GENERATOR.
WARNING: DO NOT USE INFLAMMABLE SOLVENTS OR PETROL TO CLEAN
THE AIR FILTER.