ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply 
through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.

If the plug has to be changed because it is not suitable for your socket, or 
because of damage, it must be removed and a replacement fitted, following 
the wiring instructions shown below. The old plug must be discarded safely, as 
insertion into a power socket could cause an electrical hazard.

If the colours of the wires in the power cable do not agree with the markings 
on the plug:

• The BLUE wire must be 

connected to the 
terminal which is 
marked N or coloured 
black.

• The BROWN wire must 

be connected to the 
terminal which is 
marked L or coloured 
red.

• The YELLOW AND 

GREEN wire must be 
connected to the terminal which is marked E or 

 or coloured green.

We strongly recommend that this machine is connected to the mains supply 
through a Residual Current Device (RCD)

If you are not sure, consult a qualified electrician. DO NOT try to do any 
repairs. 

WARNING! Read these electrical safety instructions thoroughly 
before connecting the product to the mains supply.

WARNING! The wires in the power cable of this product are 
coloured in accordance with the following code:

Blue = Neutral      Brown = Live     Yellow and Green = Earth

Plug must be BS1363/A approved.

Always fit 

Ensure that the outer sheath of 

Neutral

(Blue)

Live

(Brown)

Earth

(Green and 

a 13 Amp 

the cable is firmly held by the clamp

fuse.

Yellow)

Summary of Contents for Panther 10/500

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0113 50L AIR COMPRESSOR MODEL NO PANTHER 10 500 PART NO 2242105...

Page 2: ...e date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used fo...

Page 3: ...r to the recommended setting for the tool 10 When spraying flammable materials e g cellulose paint ensure that there is sufficient airflow and keep clear of any source of ignition 11 Before spraying a...

Page 4: ...mp environment Risk of accidental start up The compressor could start automatically in the event of a power cut and subsequent reset Do not carry the compressor while it is connected to the power sour...

Page 5: ...oured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We str...

Page 6: ...ELS Use a suitable spanner to attach the wheels to the compressor Use the washers and spring washer in the positions shown ATTACH THE SUPPORT FEET Insert the support feet into the position shown FIT T...

Page 7: ...CAP 1 Remove the travel plug 2 Insert the oil filler cap MOVING THE AIR COMPRESSOR Stop the compressor and disconnect it from the power supply before you move it Always use the handle To prevent dama...

Page 8: ...ck the following Set the ON OFF switch to the OFF position pushed down Make sure that the compressor is on level ground Make sure that the supply voltage matches the voltage shown on the data label CH...

Page 9: ...he air hose 3 Turn the outlet valve handle to the on position NOTE The outlet valve is shown without the air hose fitted for clarity TURNING THE COMPRESSOR ON 1 Plug the compressor into the power supp...

Page 10: ...gent SET THE OUTPUT PRESSURE When viewed from the front the left hand outlet valve is adjustable The right hand outlet valve will only supply the full reservoir pressure and is not adjustable 1 Use th...

Page 11: ...e the air hose 4 Disconnect the tool from the hose TURNING THE COMPRESSOR OFF 1 Follow steps 1 3 in Removing Tools From The Air Hose above 2 Disconnect the compressor from the power supply 3 Slowly op...

Page 12: ...fully drained RESET BUTTON This compressor has a thermal overload device If the motor gets too hot the thermal overload device cuts the power which prevents damage to the motor If the thermal overloa...

Page 13: ...ys open the drain valve to make sure that any condensate is drained off CLEAN THE AIR FILTER MONTHLY The air filter must be examined monthly more often in dusty conditions 3 Remove the filter cover fr...

Page 14: ...is switched OFF and disconnected from the mains power supply 2 Examine the non return valve and replace the gasket and valve if necessary SPECIFICATIONS Max Pressure 8 Bar Voltage 230 VAC 50 60Hz Air...

Page 15: ...mpressor does not reach the set pressure and overheats easily Compressor head gasket blown or valve broken 1 Return the machine to your nearest service agent Compressor does not start The reservoir ha...

Page 16: ...16 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com EXPLODED DIAGRAM...

Page 17: ...ight 15 Rubber gasket 16 Breath pipe 17 Crank case cover 18 Screw M5x14 19 Oil leveler washer 20 Oil leveler 21 Unilateralist valve 22 Pressure switch 23 Pressure gauge 24 Outlet valve 25 Switch brack...

Page 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 20: ......

Reviews: