8
The stove can be recessed in a suitable sized fireplace but a permanent free
air gap of at least 200 mm must be left around the sides and top and at least
50 mm at the back of the stove to obtain maximum heat output and for
access to the rear of the stove.
MINIMUM DISTANCE TO COMBUSTIBLE MATERIALS
Note: combustible material refers to any material that will degrade when
subjected to heat e.g. plaster.
Due to the heat of a hot stove, a suitable fire guard should always be used to
provide additional protection. Never allow young children to be left
unsupervised in a room containing a hot stove.
Note; If in doubt, refer to the Building Regulations 2000 Approved Document
“J”.
THE CHIMNEY
The stove is supplied with a flue pipe connector for top or rear mounting with
the fixing screws supplied. The stove should never be connected to a shared
chimney/flue system.
Flue pipes with a smaller cross-sectional area than that of the stove outlet
should never be used. Flue pipes must not project into the chimney
connector, such as to cause a restriction to the gas flow.
Fig 6
MATERIAL CLEARANCES
The stove must have a minimum clearance of 1200 mm to combustable
surfaces above. Always refer to your stove installer and if in doubt, consult
local building regulations.
It is recommended that the stove be installed at least 450 mm from
combustible materials to the side and 300 mm to the rear. However, any
household furnishings should be at least 1200 mm away from the front of the
stove as they could be adversely affected by heat.