14
OPERATING INSTRUCTIONS
Switching the air compressor ON
The compressor will make a continuous loud noise when the tank is charging -
this is normal.
1.
Lift the red On/Off switch located on
top of the air compressor.
•
The compressor will charge the
main tank to 8 bar (116 psi) then
switch off.
•
The compressor will restart
automatically whenever the
pressure in the main tank falls below
a certain level.
2.
Check the operation of the safety
valve, under pressure, daily by pulling
the ring as shown in figure 6. Air should
be released as you pull the ring and stop when the ring is released.
•
If the valve does not operate as described, or if the valve is stuck, it must
be replaced by qualified service personnel before using the compressor.
WARNING!
Do not remove or attempt to adjust the safety valve.
3.
Select the pressure you need using
the pressure regulator. See figure 7.
4.
Open the outlet tap.
Figure 10
Figure 7
Figure 6
Pressure
regulator
Output pressure
gauge