7
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
MAINTENANCE
This pump should require no maintenance other than regular cleaning.
If the pump starts to show signs of wear or damage, contact your CLARKE
dealer for advice.
CLEANING
1. Check the pump installation regularly to ensure the water inlet is clear of
leaves or other debris.
2. Take extra care to remove any debris from around the impeller.
NOTE:
Do not attempt to repair the pump yourself. Repairs must be carried
out by your CLARKE dealer, or contact the CLARKE Service
Department.
STORAGE
When the pump is not being used for extended periods, clean and dry it
thoroughly and store it indoors. If the pump is left in water, it must be run at
least once a week to prevent it from seizing up.
SPECIFICATIONS
WARNING: BEFORE CHECKING THE CONDITION OF THE PUMP, ENSURE IT
IS UNPLUGGED FROM THE MAINS SUPPLY. IF THE UNIT IS HARD WIRED,
ENSURE THE CIRCUIT BREAKER IS OPEN.
HSEC650A
HSEC651A
HSEC1400A
Part Number
7230290
7230295
7230243
Outlet Diameter
2“BSP (inc 2”BSP to 50 mm Hose Adaptor)
Voltage
230V/50hz
110V/50Hz*
230V~50Hz
Motor Wattage@ max flowrate
665W
665W
1400 W
Fuse Rating (amps)
13
13
Cable length (m)
10
10
10
IP Rating
IP68
IP68
IP68
Max. Head (m)
9.5m
9.5m
13 m
Dimensions (D x W x H) mm
240 x 180 x 420
240 x 180 x 420
228 x 305 x 478
Weight
17
17
29.85.5 kg
Maximum Depth
5m
5m
6 m
Summary of Contents for HSEC1400A