Clarke GRH125 Operating & Maintenance Instructions Download Page 6

6

VENTILATION

WARNING:

Provide at least a 10ft

opening of fresh, outside air whilst running this

heater. If proper fresh, outside air ventilation is not provided, carbon

monoxide poisoning can occur.

INSTALLATION

Read these instructions carefully. Do not allow anyone who has not read these
instructions to light, adjust or operate this heater.

Do not attempt to operate the heater with any gas other than propane

This heater, including hose and regulator assembly, must be inspected before
each use and at least annually by a qualified service person. If the hose shows
evidence of excessive abrasion or wear or if the hose is cut, it must be replaced
prior to the heater being put into operation. The replacement hose assembly
shall be that specified by Clarke International.

Positioning the Heater

The heater and propane gas cylinder must be located on a hard, flat, level
surface to minimize the risk of accidental tipping. The propane gas cylinder should
be adequately restrained to prevent accidental tipping. 

DO NOT operate this

heater with the supply cylinder in any other than the upright position.

This appliance must be located only in places where the potential for physical
damage to the appliance, or to individuals (burns), is reduced to a minimum.

This appliance produces radiant heat. Therefore, it must be located at least 6
feet away from any propane gas cylinder and must not be directed toward any
gas container within 20 feet.

The heater must be located such that it will not be exposed directly to water
spray, rain and/or dripping water.

Use of this heater in a draft/windy area decreases its efficiency. If possible, operate
the unit in a draft free area.

Summary of Contents for GRH125

Page 1: ...GAS HEATER OPERATING MAINTENANCE INSTRUCTIONS Model No GRH125 GAS HEATER 0806...

Page 2: ...400 PARTS SERVICE FAX 020 8558 3622 or e mail as follows PARTS Parts clarkeinternational com SERVICE Service clarkeinternational com PARTS SERVICE CONTACTS SPECIFICATIONS Rating BTU Output 125 000 Btu...

Page 3: ...ound you and you can look forward to it giving you long and reliable service Keep this booklet safe for future reference as any person who has not read this booklet should not be allowed to operate th...

Page 4: ...the heater where Gasoline Paint thinner or other highly flammable vapour or high dust content is present Use ONLY in well ventilated areas Provide a ventilation opening of at least 10 square feet to...

Page 5: ...eater is designed to operate with a minimum 20 pound 9 kg propane tank You may need two or more tanks or one larger tank in colder weather Use a 100 pound 45 kg tank for longer operation or in very co...

Page 6: ...that specified by Clarke International Positioning the Heater The heater and propane gas cylinder must be located on a hard flat level surface to minimize the risk of accidental tipping The propane g...

Page 7: ...ppliance DO NOT attempt to adjust this regulator It has been preset at the factory to provide safe and proper operation of the appliance Attach the regulator to the gas cylinder ensuring the cylinder...

Page 8: ...ter C Fig 2 until the pilot light ignites The pilot light may be viewed through the window shown at A Fig 2 8 NOTE If a new gas cylinder has been connected it may take some time for the gas line to be...

Page 9: ...n difficult spots 3 Inspect heater before each use Check connections for leaks Apply mixture of liquid soap and water to connections Bubbles forming show a leak Correct all leaks at once 4 Clean insid...

Page 10: ...replace thermocouple 7 Automatic control valve 7 Replace automatic control needs to be replaced valve 8 Loose wires on tip over 8 Tighten wires on tip over switch switch 9 Loose or broken wire 9 Tigh...

Page 11: ...Starter GRH125CR835 11 Axle GRH125CR820 12 Axle Brackets GRH125CR815 13 Handle GRH125CR725 14 Wheel GRH125CR810 15 Valve Supply Tube GRH125M9005 16 Clamp GRH125M9010 17 Burner Manifold GRH125M9015 18...

Reviews: