AC OVER LOAD PROTECTOR
If the AC overload protector
activates:
1. Disconnect the appliance
• Wait for 2-3 minutes.
2. Press the AC circuit breaker/reset
button shown on the right.
DC POWER (FOR CHARGING CAR BATTERIES ONLY)
1. Start the engine, See page 10.
2. Connect the battery charging
leads to the battery.
• Make sure you clamp the red
wire to the positive (+) terminal
and the black wire to the
negative (-) terminal of the
battery.
3. Connect the battery charging
leads to the DC Socket.
• The battery will begin to
charge.
4. Monitor the voltage across the battery regularly during charging and
disconnect the battery when the voltage reaches 14.4 volts.
DC OVER LOAD PROTECTOR
If the DC overload protector activates:
1. Disconnect the battery charging leads and wait for 2-3 minutes.
2. Press the DC circuit breaker/reset button to reset the generator.
WARNING: FOR YOUR SAFETY PERFORM THE FOLLOWING INSTRUCTIONS
IN THE ORDER SHOWN.
CAUTION: WHEN DISCONNECTING THE BATTERY, ALWAYS DISCONNECT
THE NEGATIVE LEAD FIRST.