Clarke ECP20A3 Operation & Maintenance Instructions Manual Download Page 9

9

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

OPERATION

1. Open any valves in the pipeline.

2. If operating the pump for the first time, prime the pump as described. on 

page 8.

NOTE: Refilling (re-priming) is only necessary if the pump has been 

drained.

3. Connect to the power supply and switch on. 

• When water starts to flow through the system check for leaks and 

correct as necessary.

• If the motor fails to start or the pump does not deliver water, refer to 

TROUBLESHOOTING. 

• Never operate the pump when not primed with water or if the inlet is 

blocked which would allow the pump to run dry, causing damage.

NOTE: Filling the suction pipe with water will speed up the priming 

process, and it is essential that a non-return valve be fitted to the 
end of the suction pipe.

4. Stop the pump by switching off the power supply.

CARE DURING USE

1. Do not allow the pump to run dry, otherwise the seal between the pump 

and motor may be damaged. If a leak occurs at this point, allowing water 
to pass from the pump to the motor, take the pump to your Clarke dealer 
for overhaul.

2. In the event of a blockage, where debris has entered the pump, it can be 

cleaned out as described under MAINTENANCE.

3. DO NOT USE for pumping chemicals or other corrosive liquids. Should 

contaminants enter the pump, flush through with water as soon as possible 
to prevent damage.

4. If the pump is being used to drain a pool, ensure there is adequate 

drainage and there is no risk of damage to property as a result of water 
being discharged. If a flexible hose must be laid across a roadway, protect 
it with wooden planking.

Summary of Contents for ECP20A3

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0517 ISS 3 2 ELECTRIC WATER PUMP MODEL NO ECP20A3 PART NO 7120410...

Page 2: ...around you and you can look forward to your purchase giving you long and satisfactory service Your CLARKE water pump has been designed to give long and trouble free service If however having followed...

Page 3: ...allow persons unfamiliar with these instructions to instal or operate the pump 6 ALWAYS ensure that the pump is properly installed to prevent it from moving during operation and that the immediate ar...

Page 4: ...ting position Mount the pump on raised blocks or a purpose built platform to protect it from flooding Some kind of anti vibration mounting is also desirable Always ensure there is adequate air circula...

Page 5: ...the Earth symbol Connect the remaining Brown Black and Grey wires to the terminals marked L1 L2 and L3 No connection to the Neutral terminal is required Due to these high currents the product must on...

Page 6: ...hose between any rigid pipework and the pump We recommend that you always use pipes hoses with a minimum diameter of 2 51 mm Any restriction in the pipeline will greatly reduce the flow Ensure that th...

Page 7: ...ing the vertical distance between the foot valve and the pump does not exceed the 8 metres specified for this pump When suction lift is used it is essential that all connections and hoses are airtight...

Page 8: ...tlet as shown NOTE As the priming hole is quite small it is necessary to fill the inlet suction pipe with water before connecting to the pump and top up through the priming port once the pipe is conne...

Page 9: ...riming process and it is essential that a non return valve be fitted to the end of the suction pipe 4 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry...

Page 10: ...om the weather If the pump is seized following a period of inactivity it may be possible to free it off Ensure the pump power supply is turned off before by inserting a screwdriver into either the inf...

Page 11: ...rime Air leaks through suction hose joints damaged hose broken clamp damaged Repair connections replace hose as necessary Blocked inlet hose Check pipeline for block age Check any inlet valve fitted i...

Page 12: ...n loss of flow Blockage of inlet pipe Check pipeline for blockage Undue vibration or noise Excessive flow of water Decrease flow of water by adjusting inlet outlet valves in system Resistance in inlet...

Page 13: ...x4 splashing water Duty Cycle S1 Continuous Supply 400V 50Hz 3ph Rated Power Input 1830 W Outlet Thread Size 2 BSP Weight 30 5 kg Length x Width x Height 450 x 242 x 325 mm Sound Pressure Level 58 0...

Page 14: ...e Plug 15 Pump Support 28 Foot 3 O Ring 16 Drops Guard 29 Stator Winding 4 Nut 17 Spring washer 30 Bearing 5 Snap Ring 18 Bolt 31 Rotor 6 Washer 19 Screw 32 Bearing 7 Key 20 Terminal Box 33 Circlip 8...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 16: ......

Reviews: