background image

3

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

TECHNICAL SPECIFICATION

SAFETY SYMBOLS

The following symbols appear on the unit.

Dimensions (L x W x H)

580 x 340 x 625 mm

Weight (empty)

18.5 kg

Fuel

Diesel/paraffin

Fuel consumption

1.9 L per hour

Fuel Tank capacity

10.5 litres

Ignition type

Direct spark

Air displacement

400 m

3

/hr

Continuous working time

6 hr (before re-fueling)

Over heating protection

120

o

C

Max output

20 kW (68242 Btu/h)

Selectable operating temperature

+5

o

C to +45

o

C

Duty cycle

S1 (continuous)

Fuel pump pressure

15 bar

Electrical supply

230V 50 Hz 1 ph

Protection degree

IPX4

Sound pressure level

65 dB LpA

Hot Surface, do not 
touch

Read these 
instructions before use

Do not cover

Summary of Contents for Devil IRD20B

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0518 iSS 3 INFRARED DIESEL HEATER MODEL NO DEVIL IRD20B PART NO 6925500...

Page 2: ...ich will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty...

Page 3: ...umption 1 9 L per hour Fuel Tank capacity 10 5 litres Ignition type Direct spark Air displacement 400 m3 hr Continuous working time 6 hr before re fueling Over heating protection 120oC Max output 20 k...

Page 4: ...eater or power cable to rain or wet conditions Any water entering the heater will increase the risk of electric shock 3 Never use the heater where petrol paint thinners or other highly flammable vapou...

Page 5: ...s responsible for informing those present of the safety precautions and of the hazards involved 2 The heater is not to be used by children or people with reduced physical sensory or mental capabilitie...

Page 6: ...e risk of electric shock 3 Keep the mains cable well away from machines and ensure an adequate electrical supply is close at hand so that the operation is not restricted by the length of the cable 4 A...

Page 7: ...ard If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connecte...

Page 8: ...which are supplied loose SAFETY SYSTEMS The unit is fitted with a temperature limit sensor which is designed to turn the heater off if the temperature should rise to an unsafe level If the sensor is t...

Page 9: ...ly if it should tip over beyond a pre determined angle PREPARATION UNPACKING 1 Remove heater from carton and remove all protective material used for shipment 2 Check the heater for any damage and noti...

Page 10: ...h filter inside the filler neck for any trapped contamination and clean out if necessary When filling the heater make sure that the heater is level and do not overfill Use a funnel or can with a long...

Page 11: ...ply 2 Set the power switch to the ON position The power on LED will illuminate and the digital temperature display will show the room temperature for up to 3 minutes Turn the temperature control knob...

Page 12: ...CAUSE SOLUTION FO Operation error 1 Heater is switched on before being plugged in 1 Disconnect from power supply switch off and then plug in again before switching on F1 Photocell error 1 No fuel 2 F...

Page 13: ...sk dealer to clean re gap replace spark plug 3 Clean replace fuel filter 4 Ask dealer to clean replace nozzle 5 Rinse out fuel tank with clean fresh fuel 6 Return to dealer 7 Return to dealer for repa...

Page 14: ...e fuel has become contaminated with dirt or water empty the tank and refill with fresh fuel 4 The fuel filter should be removed and inspected for cleanliness before refilling the tank If foul remove a...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...