TROUBLESHOOTING

If this does not solve your problem, please contact the Clarke service 
department.

PROBLEM

SOLUTION

PUMP WILL 
NOT START

1. Make sure that the power is switched on.

2. Check fuse (consult an electrician if in doubt).
3. If extension lead is fitted, check connections (consult an 

electrician if in doubt).

4. Internal thermal cut-out has not re-set. Leave for 5-10 

minutes and try again.

5. The impeller may be jammed. Disconnect from the mains 

supply and remove any objects that may be obstructing 
the impeller. 

6. Float switch may be jammed against side wall, or 

prevented from moving. 

7. Water level too low - float switch in OFF position - lift float 

to check switch.

8. If the pump still fails to start, consult your CLARKE dealer 

for advice. 

PUMP WILL 
START BUT NOT 
PUMP

1. Check that the inlet is not blocked.
2. Check that the discharge tube is not clogged or 

obstructed.

3. The head may be too great, i.e. you are trying to lift the 

water too great a distance for the pump to cope with. 
(“Specifications” on page 7).

4. Air bubble in the pump, produced during immersion. 

immerse the pump again, at an angle, and shake it whilst 
lowering to remove any air trapped in the system.

5. Impeller may be damaged - Consult your CLARKE dealer.

PUMP WILL 
NOT STOP

1. Float switch may be prevented from moving to the fully 

down position.

2. Float switch may be faulty. Consult your CLARKE dealer 

for advice.

PUMP STOPS 
RUNNING

1. Thermal overload has operated. Leave for 5-10 minutes 

and try again.

2. Pump has run dry, or float switch has cut in.

3. A foreign object has jammed the impeller.

Summary of Contents for CWP1000A

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0814 SUBMERSIBLE CLEAN WATER PUMP MODEL NO CWP1000A PART NO 7230097...

Page 2: ...invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no prod...

Page 3: ...and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump explosive...

Page 4: ...rnational com or Service clarkeinternational com PART IDENTIFICATION Remove all packaging and make sure that the unit contains no visible damage Dispose of all packaging appropriatly 1 FLOAT SWITCH 4...

Page 5: ...t be connected to the terminal which is marked N or coloured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the...

Page 6: ...erged before the pump is switched on 3 Connect the mains plug to a high sensitivity residual current device RCD which has a tripping current of less then 30mA 4 Switch the mains power supply on The pu...

Page 7: ...e Repairs must be carried out by your CLARKE dealer or contact the CLARKE Service Department on 020 8988 7400 STORAGE When the pump is not being used for extended periods clean and dry it thoroughly a...

Page 8: ...OFF position lift float to check switch 8 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the dis...

Page 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 10: ...d 3 Bottom Caslng Cover 17 Motor Frame 31 Float Switch 4 Bolt 18 Stator 32 Power Cable 5 Spring Washer 19 Fluid Diffuser 33 Screw 6 lmpeller 20 Corrugated Sheet 34 Screw 7 O Ring 21 Screw 35 O Ring 8...

Page 11: ...ational com ACCESSORIES Layflat Hoses Assorted Hose Clip Set CHT672 Available in 100 metre coils or per meter Available in 1 3 Diameter 26 piece assorted hose clip set in various sizes Including 8 x16...

Page 12: ......

Reviews: