Clarke CWM20 Operating & Maintenance Instructions Download Page 5

5

ELECTRICAL CONNECTIONS

Connect the mains lead to a standard 230 Volt (50Hz) electrical supply through an
approved plug or a suitable fused isolator switch.

For your own safety, we recommend that this unit is fitted with a Residual Current Device
(RCD).

WARNING: THIS APPLIANCE MUST BE EARTHED.

IMPORTANT: The wires in the mains lead are coloured in accordance with the following
code:

Green and Yellow

-

Earth

Blue

-

Neutral

Brown

-

Live

As the colours of the flexible cord of this appliance may not correspond with the
coloured markings identifying terminals in your plug, proceed as follows:

Connect GREEN & YELLOW coloured cord to plug terminal marked with a letter
“E” or Earth symbol “    “ or coloured GREEN or GREEN & YELLOW.

Connect the BROWN cord to the terminal marked “L” or coloured RED.

Connect the BLUE cord to the terminal marked “N” or coloured BLACK.

Fuse Rating

The fuse in the plug for this appliance must be rated at 

3 amps 

and any replacement

must be ASTA approved to BS1362.

If this appliance is fitted with a plug which is moulded onto the electric cable (i.e. non-
rewirable) please note:

1.

The plug must be thrown away if it is cut from the electric cable. There is a danger of
electric shock if it is then inserted in a socket outlet.

2.

Never use the plug without the fuse cover fitted.

3.

Should you wish to replace a detachable fuse carrier, ensure that the correct
replacement is used (as indicated by marking or colour code).

4.

Replacement fuse covers can be obtained from your local dealer or most electrical
stockists.

Summary of Contents for CWM20

Page 1: ...MOBILE PARTS WASHER MOBILE PARTS WASHER MODEL No CWM20 Part No 7630925 OPERATING MAINTENANCE INSTRUCTIONS GC0418 ...

Page 2: ... been abused or tampered with in any way or not used for the purpose for which it is intended The reason for return must be clearly stated This guarantee does not affect your statutory rights ENVIRONMENTAL RECYCLING POLICY Through purchase of this product the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment recycling re...

Page 3: ...loses lid in case of fire Built in replaceable filter Easy maintenance solvent pump 230V AC CONTENTS Guarantee 2 Specifications 2 Features 3 Contents 3 Safety precautions 4 Electrical connections 5 Assembly 6 Operation 8 Cleaning and maintenance 9 Parts diagram 10 Parts list 11 ...

Page 4: ...f in doubt DO NOT use the machine Consult your local CLARKE dealer 6 ALWAYS disconnect the mobile parts washer from the power supply before carrying out any maintenance or cleaning of the mobile parts washer 7 ALWAYS keep work area clean Cluttered areas and benches invite accidents mop up accidental spillages of degreaser immediately 8 ALWAYS ensure that adequate lighting is available 9 ALWAYS kee...

Page 5: ...r E or Earth symbol or coloured GREEN or GREEN YELLOW Connect the BROWN cord to the terminal marked L or coloured RED Connect the BLUE cord to the terminal marked N or coloured BLACK Fuse Rating The fuse in the plug for this appliance must be rated at 3 amps and any replacement must be ASTA approved to BS1362 If this appliance is fitted with a plug which is moulded onto the electric cable i e non ...

Page 6: ...e using 2 M8x40mm hex bolts 4 flat washers and 2 hex nuts 3 Place the tray into position and fix in place using 2 M8x40mm hex bolts 4 flat washers and 2 hex nuts 4 Position the second side post as shown and secure using 2 M8x40mm hex bolts 4 flat washers and 2 hex nuts 1 2 3 4 Supporting board Bolt Bolt Castor Bolt Tray ...

Page 7: ... ASSEMBLY 5 Position the draining tray as shown above and fix in place using 4 M8x40mm hex bolts 8 flat washers and 4 hex nuts 5 6 6 Slide the oil tank into position as shown above Draining Tray Oil Tank ...

Page 8: ...the pump close the lid and disconnect the power supply 6 Remove gloves and goggles and store safely Note To prevent an accident any spillages should be mopped up immediately IMPORTANT 1 The lid stay incorporates a safety device in the form of a thermally activated safety link which closes the lid in the event of fire The link is non resetting and must be replaced in the event of it operating 2 Do ...

Page 9: ...ning tray below and into the oil tank for disposal Make sure that the oil tank does not over fill Changing the filter 1 Lift out the parts shelf 2 Slide the filter holder up from the pump as shown 3 Remove the filter from the holder and replace 4 Refit the filter holder Caution Do not use the parts washer without the filter in place ...

Page 10: ...10 PARTS DIAGRAM ...

Page 11: ...015 16 Cable Strain Relief HTCWM20016 17 Switch Box HTCWM20017 18 Screw M4x10 HTCWM20018 19 Flat Washer M4 HTCWM20019 20 ON OFF Switch HTCWM20020 21 Wire Guard HTCWM20021 22 Hex Nut M4 HTCWM20022 23 Spring Washer HTCWM20023 24 Flange Wire HTCWM20024 25 Supporting Board RightHTCWM20025 26 Flexible Nozzle HTCWM20026 27 Pump Housing Cover HTCWM20027 28 Filter Cover HTCWM20028 29 Filter HTCWM20029 30 ...

Page 12: ......

Reviews: