Clarke CM265 User Instructions Download Page 2

SETUP AND OPERATION

Loosen the slide clamp screw.

Press the ON button to switch the calipers on, select the required measuring unit by pressing the inch/mm mode switch.

Apply pressure to the thumb roller and close the caliper jaws, press the ‘ZERO’ button to zero the display.

MEASURING APPLICATIONS:

Measurement of

external diameter.

Measurement of

internal diameter.

Measurement

of steps.

Measurement

of depth.

GENERAL VIEW

BATTERY REPLACEMENT

When the display constantly flashes the battery requires
replacement. Slide off the battery compartment cover
and insert a new battery with the positive (+) side
facing up.

For spare parts and servicing, please contact your nearest dealer, or CLARKE International on:

020 8988 7400 or email: [email protected]

[email protected]

CLARKE International, Hemnall Street, Epping, Essex, CM16 4LG

Low battery - Replace battery.

Electronic fault - Remove battery & re-insert after 30 seconds.

Battery flat or in poor contact - Re-insert or replace battery.

Dirty sensor - Clean caliper thoroughly with compressed air.

LCD Display

Inside Measuring Faces

Depth Measuring Blade

Step Measuring Faces

Beam

Main Scale

Battery Compartment Cover

Manufacturer Access Cover (Keep Closed)

Slide Clamp Screw

Thumb Roller

Power OFF Switch

ON / Display ‘Zero’ Switch

Inch / mm Mode Switch

Outside Measuring Faces

TROUBLE SHOOTING

:

FAULT:

CAUSE/SOLUTION:

Display flashes constantly.

Display fails to change when slider is moved.

Display fails to function.

Measuring becomes less accurate.