background image

7

OPERATING INSTRUCTIONS

WARNING!

WAIT UNTIL THE ANVIL HAS STOPPED ROTATING BEFORE OPERATING THE

DIRECTION CONTROL SWITCH.

USING THE DIRECTIONAL CONTROL BUTTON

The direction control button should be used as follows.

1

For normal tightening, the impact wrench should be operated in the forward (F)
direction.

2

For loosening, the impact wrench should be operated in the reverse (R) direction.

Direction control button in

forward position

Direction control button in

reverse position

FITTING THE IMPACT SOCKET

1

Select the impact socket you require

WARNING!

NEVER use standard sockets. These may

shatter with serious consequences. Use

ONLY Impact sockets.

2

Push the inpact socket onto the anvil
as shown.

Summary of Contents for air CAT101

Page 1: ...1 2 IMPACT WRENCH 1 2 IMPACT WRENCH MODEL No CAT101 Part No 3110857 OPERATION MAINTENANCE INSTRUCTIONS 0707 ...

Page 2: ...at any time without prior notice Always consult the machine s data plate GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty...

Page 3: ...ay alert and use common sense Do not operate the impact wrench when you are tired or under the influence of alcohol drugs or medication Always wear eye protectors when using the impact wrench Eye protectors must provide protection from flying particles from the front and the side Always wear ear protectors when using the impact wrench Do not overreach Keep proper footing and balance at all times N...

Page 4: ...could fail due to vibration DO NOT force or misuse the tool It will do a better and safer job at the rate for which it was designed DO NOT remove any labels Damaged labels should be replaced This tool vibrates with use Vibration may be harmful to your hands or arms Stop using the tool if discomfort a tingling feeling or pain occurs Seek medical advice before resuming use NEVER use standard sockets...

Page 5: ...lated compressed air as a power source for the impact wrench Air compressors used with the impact wrench must comply with the appropriate European Community safety directives A build up of moisture or oil in the air compressor will accelerate wear and corrosion in the impact wrench Never exceed the maximum operating pressure for the impact wrench AIR HOSE The air hose must be rated at least 150 of...

Page 6: ... 2 Connect the other end of the hose to the compressor 3 Your impact wrench is now ready for use You can fit a whip hose with a quick fit coupling if required available from your Clarke dealer WARNING COMPRESSED AIR CAN BE DANGEROUS ENSURE THAT YOU ARE THOROUGHLY FAMILIAR WITH ALL PRECAUTIONS RELATING TO THE USE OF COMPRESSORS AND COMPRESSED AIR SUPPLY ...

Page 7: ...pact wrench should be operated in the forward F direction 2 For loosening the impact wrench should be operated in the reverse R direction Direction control button in forward position Direction control button in reverse position FITTING THE IMPACT SOCKET 1 Select the impact socket you require WARNING NEVER use standard sockets These may shatter with serious consequences Use ONLY Impact sockets 2 Pu...

Page 8: ... Refer to the compressor instruction book for the procedures to shut down and release the compressed air 2 Once the pressure has been released disconnect the air supply hose from the impact wrench 3 Store the impact wrench safely in its box in a dry secure environment Squeeze OPERATING THE IMPACT WRENCH 1 Locate the socket over the nut to be tightened or loosened 2 Squeeze the trigger to start the...

Page 9: ...f the impact wrench CLEANING Keep the body of the impact wrench clean and free from debris Grit or gum deposits in the tool may reduce efficiency SERVICE AND REPAIR All servicing and repair must be carried out by qualified service technicians NOTES Please note that factors other than the tool may effect its operation and efficiency such as reduced compressor output excessive drain on the airline m...

Page 10: ...Anvil 19 KL504W19 Hammer Cage 20 KL504W20 Hammer Pin 21 KL504W21 Hammer Dog 22 KL504W22 Drive Cam 23 KLSP008 Pin 24 KL504W24 Cylinder 25 KL504W25 Rotor 26 KL504W26 Rotor Blade 27 KL504W27 Rear End Plate 28 KLCA6001 Ball Bearing 29 KL504W29 Front End Plate 30 KLSP006 Pin 31 KL504W31 Spring 32 KL504W32 Pin 33 KL504W33 Gasket 34 KL504W34 Rear Cover 35 KLSH0031 Screw Spring Washer 36 KL504W37 Front Ru...

Page 11: ...values appear in the declaration on page 2 HAND ARM VIBRATION You will note that a third value is given in the specification the highest measured reading in a single plane This is the maximum level of vibration measured during testing in one of the axes and this should also be taken into account when making a risk assessment a values in excess of 2 5 m s2 are considered hazardous when used for pro...

Page 12: ......

Reviews: