7
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
EARTH POINT
1. Earth the generator by connecting
a suitable grounding wire to the
earth point.
NOTE:
Connect the other end of the
earthing wire to a copper or
brass grounding rod that is driven
into the ground.
CHECKING THE ENGINE OIL LEVEL
1. Turn the dipstick anti-clockwise
and remove from the oil filler tube.
2. Wipe the dipstick with a clean
cloth.
3. Insert the dipstick back into the oil
filler tube and then remove it
again. Do not screw in the oil filler
cap/dipstick when doing this.
4. If the oil level is at or below the ‘L’
mark on the dipstick, add oil to
the crankcase.
• Fill until the oil reaches the
threads in the oil fill tube.
• Oil capacity is 0.36L.
• We recommend the use of
SAE15W40 oil in this generator.
available from your Clarke
dealer.
5. Replace the oil filler cap.
WARNING: FAILURE TO PROPERLY GROUND THE GENERATOR CAN RESULT
IN ELECTROCUTION.
WARNING: TO CARRY OUT THIS CHECK, PLACE THE GENERATOR ON LEVEL
GROUND WITH THE ENGINE SWITCHED OFF.
WARNING: TAKE CARE NOT TO TOUCH ANY HOT PARTS OF THE
GENERATOR WHEN CHECKING THE OIL LEVEL.