• Remove the test leads from the meter before you 

open the battery door or measure AC current.

• Do not operate the meter with the battery door or 

portions of the case removed or loosened.

• To avoid false readings, which could lead to 

possible electric shock or personal injury, replace 
the batteries as soon as the low battery indicator 
appears.

• Before using the clamp jaws to clamp the 

conductor to be measured, make sure that all the 
test leads have been removed from the clamp 
meter.

• Remove test leads from the meter and remove the 

clamp jaw from the clamped conductor before 
opening the meter case or the battery door.

• Remaining endangerment: When an input terminal 

is connected to dangerous live potential it is to be 
noted that this potential at all other terminals can 
occur!

• CATII - Measurement Category II is for 

measurements performed on circuits directly 
connected to low voltage installation. (Examples 
are measurements on household appliances, 
portable tools and similar equipment.) Do not use 
the meter for measurements within Measurement 
Categories III and IV.

CAUTION

To avoid possible damage to the meter or to the 
equipment under test, follow these guidelines:

Summary of Contents for 8133826

Page 1: ...USER INSTRUCTIONS ORIGINAL INSTRUCTIONS DL0421 Rev 2 OPEN JAW DIGITAL MULTIMETER MODEL NO CDM85 PART NO 8133826...

Page 2: ...against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found t...

Page 3: ...ts clarkeinternational com or Service clarkeinternational com ELECTRICAL SYMBOLS AC Alternating Current DC Direct Current Dangerous voltage may be present Important safety information Refer to the man...

Page 4: ...w Used to clamp the conductor to be measured to get more accurate reading the conductor should be in the centre of the jaws 5 V Q 0 Jack Plug0in jack for the red Positive test lead 2 Trigger Used to o...

Page 5: ...d on the LCD as an indicator To exit press the button again 4 COM Jack Plug in jack for the black Negative test lead Display 3 1 2 Digit LCD Overrange Indication 1 Shown on LCD Sampling Rate Approxima...

Page 6: ...operates abnormally Protection may be impaired When in doubt have the meter serviced Do not operate the meter around explosive gas vapor or dust Do not apply more than the rated voltage as marked on...

Page 7: ...test leads have been removed from the clamp meter Remove test leads from the meter and remove the clamp jaw from the clamped conductor before opening the meter case or the battery door Remaining endan...

Page 8: ...uctor OPERATING INSTRUCTIONS MEASURING DC VOLTAGE 1 Insert the plug of the black test lead to the COM jack the plug of the red test lead to the V jack 2 Set the rotary switch to 600V position 3 Connec...

Page 9: ...ading c Don t touch the conductor with your hand or skin 4 Read the reading on the display MEASURING RESISTANCE 1 Insert the plug of the black test lead to the COM jack the plug of the red test lead t...

Page 10: ...stance being measured is less than about 30 the buzzer will sound MEASURING DIODE 1 Insert the plug of the black test lead to the COM jack the plug of the red test lead to the V jack the polarity of t...

Page 11: ...ted input voltage 600Vrms DC VOLTAGE Input impedance 9M Maximum permited input voltage 600Vrms RESISTANCE Range Resolution Accuracy Overload Protection 600V 1V 1 2 3 DC 600V AC 600Vrms Range Resolutio...

Page 12: ...wave Frequency range 50 60Hz AUDIBLE CONTINUITY DIODE Range Resolution Accuracy Overload Protection 20A 10mA 3 0 5 500A 30 Seconds 200A 100mA 2 5 5 500A 30 Seconds 400A 1A 2 5 5 500A 30 Seconds Range...

Page 13: ...ollows 1 Make sure that no object is clamped in the jaws 2 Turn the meter off and remove the test leads 3 Shake out any dirt that may be in the jacks 4 Soak a new swab with alcohol Work the swab aroun...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY UKCA...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY CE...

Page 16: ...16 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com...

Reviews: