![Clarke 7610143 Assembly & Operating Instructions Download Page 5](http://html1.mh-extra.com/html/clarke/7610143/7610143_assembly-and-operating-instructions_2615017005.webp)
5
6A.
CML3 AIR
Using all precautions with regard to using
Air equipment - REFER TO THE AIR
COMPRESSOR MANUAL, connect a
suitable air hose equiped with a snap on
type connector to the Hand Controller,
shown in Fig. 5.
The hand controller is located on the end
of the hose leading to the hydraulic ram.
Start the compressor with the outlet pressure set to zero, then open the outlet tap.
Set the output pressure to between 8 - 13 bar, depending upon compressor size.
Taking all precautions, as previously described, press down the operating lever of the
hand controller. The ram will begin to operate and the platform will rise. Be prepared to
release the lever immediately should any part of the lift become snagged.
Raise the platform to its maximum height, then proceed as described in para. 7 on page
4.
NOTE: A 1HP (MIN) Air compressor is recommended for operation, although a 2HP machine
will increase the speed of operation.
To Lower the Lift
As the weight of the table is taken by the Locking Bar, it is necessary to pump the Foot
Lever slightly in order to take the strain, and then remove the Locking Bar,
Visually check under and around the Lift to ensure that no obstacle will interfere when
lowering the table.
Depress the Lowering Lever until the table is at its lowest position.
To manoeuvre the Lift around the workshop, screw up the stabilisers to allow the castors
to function. For storage purposes, always screw the stabilisers down, to take the weight
off the castors.