background image

6

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

INSTALLATION OF THE PUMP

IMPORTANT: The pump MUST NOT be connected to the mains power supply 
until all hose/pipe installations are completed.

If any part of the system is to be connected to the mains water supply, do 
ensure that you comply with your local water authority regulations.

Because of the variety of possible installations, no plumbing accessories are 
supplied as standard with your pump. However, accessories designed 
specifically for this range of pumps are available from your CLARKE dealer.

The pump must always be installed and operated in a horizontal position i.e. 
with the outlet port facing vertically upwards. The fixing holes in the base 
should be used as necessary to secure the pump firmly in its operating 
position. Also, ensure that there is adequate air circulation around the motor.

Avoid situations where there is the risk of water coming into contact with the 
outside of the pump. Neither the motor or the terminal box are designed to be 
waterproof.

These notes are for guidance on 
how to achieve a proper 
working system.

The schematic diagram 
opposite illustrates a typical 
pipework installation.

The suction lift i.e. the vertical 
distance between the water 
level and the pump should not 
exceed the distance specified 
for your pump.

A foot valve and filter should be fitted to the lower 

end of the suction hose, as illustrated below, so as to 
help retain water in the suction system and to 
prevent the possibility of large foreign bodies entering 
the pump body.

A 1” BSP hose adapter will be required for connection 
to the inlet port. This is available from your dealer.

The performance of your pump will be effected by 
the diameter of the inlet pipe - any restriction will 
greatly reduce the flow. We strongly recommend 
that you use a diameter pipe which is as large as 
practicable, with a suitable reducer for connection 
to the 1” BSP inlet adapter. 

Summary of Contents for 7230670

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1220 WATER PUMP MODEL NO CBM240E PART NO 7230670...

Page 2: ...ture for a period of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or t...

Page 3: ...ernational com SPECIFICATION PUMP PERFORMANCE CURVE Maximum Delivery 100 L min Maximum Head 14 m Maximum Suction Lift 7 5 m On Off Pressure 1 6 4 8 Bar Ingress Protection Rating IPx4 Supply 230V 50Hz...

Page 4: ...is properly installed to prevent it from moving during operation and that the immediate area surrounding the pump is kept clear 6 ALWAYS maintain the pump with care and keep it clean for best safest...

Page 5: ...er cable must agree with the markings on the plug Connect the BLUE wire to the terminal marked N Connect the BROWN wire to the terminal marked L Connect the YELLOW AND GREEN wire to the terminal marke...

Page 6: ...ation around the motor Avoid situations where there is the risk of water coming into contact with the outside of the pump Neither the motor or the terminal box are designed to be waterproof These note...

Page 7: ...dy from entering the pump This is particularly important in the case of multi stage pump such as the CBM240E A filter specifically designed for all pumps in the range is available from your CLARKE dea...

Page 8: ...of the pump chamber and slowly fill the pump with water until all air is expelled NOTE If a filter is fitted to your pump it is recommended that you remove the brass plug on top of the unit and fill...

Page 9: ...clear blockage Pump fails to prime Air leaks through suction hose joints damaged hose or damaged clamp Repair connections replace hose as necessary Blocked inlet hose Check pipeline for block age Chec...

Page 10: ...flow of water by adjusting inlet outlet valves in system Resistance in inlet pipe caused by obstruction Check pipe and clean out as necessary Loose rotating component Return to your dealer for repair...

Page 11: ...pump If you suspect the pump is blocked by silt leaf debris etc disconnect it from the power supply and back flush to clear any blockage using a garden hose You will need to disconnect the outlet hose...

Page 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS CBM240E...

Page 13: ...ring 35 O ring 8 End flange casting 36 Capacitor holder 9 O ring 37 Spring washer 10 O ring 38 Cable holder 11 Impeller 39 Earth screw 12 Pump body 40 Washer 13 Nut 41 Wave washer 14 Washer 42 Spring...

Page 14: ...onal com or Service clarkeinternational com ACCESSORIES 1 BSP Hose adaptor 90o bend female Part No 7950190 1 BSP Plastic Foot Valve Filter FVF10 Part No 7950680 1 dia Reinforced Suction Delivery Hose...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 16: ......

Reviews: