MAINTENANCE

This pump should require no maintenance other than regular cleaning. If the 
pump starts to show signs of wear or damage, contact your CLARKE dealer for 
advice.

CLEANING

1. Check the pump installation regularly to ensure the water inlet is clear of 

leaves or other debris. Take extra care to remove any debris from around 
the impeller.

NOTE:

Do not attempt to repair the pump yourself, as you may damage the 
waterproof seal and invalidate your guarantee. Repairs must be 
carried out by your CLARKE dealer, or contact the CLARKE Service 
Department, on 020 8988 7400.

STORAGE

When the pump is not being used for extended periods, clean and dry it 
thoroughly and store in indoors. if the pump is left in water, it must be run at 
least once a week to prevent it from seizing up.

SPECIFICATIONS

WARNING: BEFORE CHECKING THE CONDITION OF THE PUMP, ENSURE IT 
IS UNPLUGGED FROM THE MAINS SUPPLY. IF THE UNIT IS HARD WIRED, 
ENSURE THE CIRCUIT BREAKER IS OPEN.

Voltage

230V~50Hz

Outlet Thread Diameter

2“ BSP

Power 1300W

Maximum Head Height

11 m

Maximum Depth

7 m

Maximum Flow

417 l/min

Maximum Water Temperature

35

o

C

Maximum Particle Size

40 mm

Weight

7.8 kg

Cable Length

10 m

Dimensions (D x W x H) 

222  x 218 x 427 mm

Summary of Contents for 7230604

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC 1221 ISS4 1300W SUBMERSIBLE PUMP MODEL NO CSV4A PART NO 7230604...

Page 2: ...iod of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with i...

Page 3: ...r use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 DO NOT pump exp...

Page 4: ...BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the term...

Page 5: ...le hose not supplied to the pump outlet Suitable hoses are available from your local Clarke dealer FITTING THE HOSE ADAPTER 2 step adapter 2 hose 1 BSP 3 step adapter 1 hose 1 BSP 1 hose 1 Screw the 2...

Page 6: ...ect the mains plug to the mains supply Always use a high sensitivity residual current device RCD which has a tripping current of less then 30mA 2 Switch the mains power supply on The pump will begin t...

Page 7: ...guarantee Repairs must be carried out by your CLARKE dealer or contact the CLARKE Service Department on 020 8988 7400 STORAGE When the pump is not being used for extended periods clean and dry it thor...

Page 8: ...moving 7 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the outlet is not clogged or obstructed...

Page 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS LIST DIAGRAM...

Page 10: ...Gland 30 Locating Ring 10 16uf Capacitor 31 Adjustable Washer 11 Ground Cover 32 Impeller 12 Nylon Secure Pressing Cap 33 Washer 13 Nylon Secure Pressing Cap 34 Nut 14 Rubber Clip 36 Self Tapping Scr...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATIONS OF CONFORMITY...

Page 12: ......

Reviews: