Clarke 7230560 Operation & Maintenance Instructions Manual Download Page 4

4

ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply 
through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.

If the plug has to be changed because it is not suitable for your socket, or 
because of damage, it must be removed and a replacement fitted, following 
the wiring instructions shown below. The old plug must be discarded safely, as 
insertion into a power socket could cause an electrical hazard

.

If the colours of the wires in the power cable do not agree with the markings 
on the plug.

• The BLUE wire must be 

connected to the 
terminal which is 
marked N or coloured 
black.

• The BROWN wire must 

be connected to the 
terminal which is 
marked L or coloured 
red.

• The YELLOW AND 

GREEN wire must be 
connected to the terminal which is marked E or 

 or coloured green.

AN APPROVED RESIDUAL CURRENT DEVICE (RCD) WHICH HAS A TRIPPING 
CURRENT OF LESS THAN 30 mA MUST BE USED.

If you are not sure, consult a qualified electrician. DO NOT try to do any 
repairs.

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS 
SUPPLY.

WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE 
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:

 

BLUE = NEUTRAL      BROWN = LIVE     YELLOW AND GREEN = EARTH

Plug must be BS1363/A approved.

Always fit 

Ensure that the outer sheath of 

Neutral

(Blue)

Live

(Brown)

Earth

(Green and 

a 13 Amp 

the cable is firmly held by the clamp

fuse.

Yellow)

Summary of Contents for 7230560

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC11 18 ISS 2 ORIGINAL INSTRUCTIONS SUBMERSIBLE WATER PUMPS MODEL NO CSE2 CSD3 CSV1A CSV2A PART NO 7230560 7230610 7230580 7230600 ...

Page 2: ...switch will rise and start the pump As the water level falls so will the float switch until it stops the pump Float switches are factory set to provide the correct on off switching mode however you can adjust the level at which the pump cuts out by sliding the float switch cable in its clip attached to the handle to either shorten or lengthen as required The shorter the cable the earlier it will c...

Page 3: ...itted the float switch cable 9 DO NOT run the pump with the body exposed for longer than 10 minutes 10 DO NOT install the pump on sand or ground which is likely to shift 11 Do not use the pump if the water is liable to freeze as this can cause damage to the pump Remove the pump from the water and store it in a frost free location 12 If the pump is to be used where there may be silt or mud for exam...

Page 4: ...or coloured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green AN APPROVED RESIDUAL CURRENT DEVICE RCD WHICH HAS A TRIPPING CURRENT OF LESS THAN 30 mA MUST BE USED If you are not sure consult a qualified electrician DO NOT try to do any repairs WARNING READ THESE...

Page 5: ...iciency we strongly recommend that you connect a 1 diameter hose to the multi hose adapter Alternatively you may remove the multi adapter altogether and screw on a 1 BSP hose adapter The pump is completely submersible and should be placed in a vertical position on a solid flat surface placing the pump on a couple of house bricks if required SUITABLE HOSES AND SPARE REPLACEMENT MULTI HOSE ADAPTERS ...

Page 6: ...ter is above a pre determined level The pump will begin to drain water As the water level falls so will the float switch until it stops the pump 4 Disconnect the pump from the mains power supply when finished These pumps are fitted with automatic thermal overload protection If the pump overheats due to an obstruction in the pump or pumping warm water for example it will shut off automatically Swit...

Page 7: ...lease contact the Clarke service department CLEANING 1 Check the pump installation regularly to ensure the base inlet is clear of leaves or other debris These pumps have screwless fittings at their base allowing the removal of the plastic cover by prising the two release clips apart in the direction of the arrows This allows better access to the cavity at the bottom should the pump become badly cl...

Page 8: ...heck switch PUMP WILL START BUT NOT PUMP 1 Check to ensure strainer is not blocked 2 Discharge tube clogged or obstructed 3 The head may be too great i e you are trying to lift the water too great a distance for the pump to cope with See specifications on page 2 4 Air bubble in the pump produced during the plunge Plunge the pump again at an angle and shake it whilst lowering to remove any air trap...

Page 9: ...9 DECLARATION OF CONFORMITY ...

Page 10: ...10 EXPLODED PARTS DIAGRAM CSV1A 2A ...

Page 11: ...Ceramic Shaft Bearings LDS3101001 LDS3101002 18 Bearing LDP1180001 LDP1180001 19 Washer LDP1120007 LDP1120007 20 Lip Seal LDP1210001 LDP1210001 21 Stator LDS3410004 LDS3410017 22 Joint O ring LDP1200007 LDP1200007 23 Pump Housing LDS3500206 LDS3500207 24 Joint O ring LDP1200009 LDP1200009 25 Elbow with O ring LDS3600111 LDS3600111 26 Washer LDP1120006 LDP1120006 27 Nut LDP1110005 LDP1110005 28 Imp...

Page 12: ...12 EXPLODED PARTS DIAGRAM CSE2 ...

Page 13: ...3 Screw LDP1100090 14 Insulation disc LDS3500106 34 Screw LDP1100014 15 Upper flange LDS3120005 35 Washer LDP1120017 16 Wave washer LDP1120002 36 Ball LDP1180003 17 Ceramic shaft with bearings LDS3101002 37 Twin Lip Seal LDP1210004 18 Bearing LDP1180001 38 Joint Ring LDP1200002 19 Washer LDP1120007 39 Step Fitting O ring LDS3600162 20 Lip seal LDP1210001 40 V ring Joint LDP1210002 CSE2 ENVIRONMENT...

Page 14: ...14 EXPLODED PARTS DIAGRAM CSD3 ...

Page 15: ...LDP1120003 36 Joint O ring LDP1200014 15 Washer LDP1120051 37 Diffuser LDS3250006 16 Insulation disc LDS3500106 38 Diffuser cap LDS3500611 17 Upper flange LDS3120005 39 Washer LDP1120014 18 Wave washer LDP1120002 40 Nut LDP1110009 19 Bearing LDP1180001 41 Filter ring LDS3220006 20 Shaft with bearings LDS3101004 42 Filter base LDS3500743 21 Washer LDP1120007 43 Screw LDP1100017 22 Lip seal LDP12100...

Page 16: ......