USING THE PUMP

1. Fit the adaptor if required as shown, 

then connect a suitable hose (not 
supplied) to the pump outlet.

• Suitable hoses are available from 

your local Clarke dealer.

2. Place the pump on a flat surface in 

the area that you want to drain. 

• If there is sediment in the water, the 

pump should be placed vertically 
on house bricks, or similar.

• Ensure the pump is positioned with adequate space so that the 

movement of the float switch is not restricted - recommended minimum 
area of 50 x 50 cm.

• ALWAYS raise and lower the pump using a rope attached to the lifting 

handle.

• Take all necessary precautions as described on page 3. 

• The pump inlet must be fully submerged before the pump is switched on.

3. Connect the plug to the power supply.

4. Switch the mains power supply on.

• The pump will begin to drain water.

• As the water level falls, so will the float switch, until it stops the pump.

• You can adjust the position at which the float switch lead clips to the 

side of the pump, If the length of the float switch lead is short the pump 
will turn on and off earlier.

5. When the pumping operation is finished, disconnect the pump from the 

mains power supply.

WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE 
PUMP IF IT IS DAMAGED IN ANY WAY.

WARNING: THE WATER BEING PUMPED WILL BE POLLUTED IF THIS PUMP 
BECOMES DAMAGED AND LUBRICANT WITHIN THE PUMP ESCAPES.

CAUTION: DO NOT ALLOW THE PUMP TO RUN DRY

Summary of Contents for 7230102

Page 1: ...FOR USE WITH A 110V SUPPLY ONLY OPERATION MAINTENANCE INSTRUCTIONS LS0620 ISS 5 ORIGINAL INSTRUCTIONS SUBMERSIBLE DIRTY WATER PUMP MODEL NO DWP210A PART NO 7230102...

Page 2: ...proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be return...

Page 3: ...r use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump exp...

Page 4: ...international com or Service clarkeinternational com PART IDENTIFICATION Remove all packaging and make sure that the unit displays no visible damage Dispose of all packaging appropriately 1 WATER INLE...

Page 5: ...the rear section 2 Rotate the cable clamp clear of the terminals 3 Feed the cable through the rear gland in the plug 4 Remove the cable sheath to the required lengths as shown in the diagram 5 Termina...

Page 6: ...d to the lifting handle Take all necessary precautions as described on page 3 The pump inlet must be fully submerged before the pump is switched on 3 Connect the plug to the power supply 4 Switch the...

Page 7: ...r for advice CLEANING 1 Check the pump installation regularly to ensure the water inlet is clear of leaves or other debris 2 Take extra care to remove any debris from around the impeller NOTE Do not a...

Page 8: ...ECIFICATIONS DWP210A Voltage 110V 50Hz Outlet Diameter 2 BSP inc 2 Adaptor Rated input Power 940W Power at Maximum Flow 1140 W Maximum Head Height 10 m Maximum Output 567 l min Maximum Depth 2 m Max W...

Page 9: ...switch in OFF position lift float to check switch 8 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check t...

Page 10: ...10 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 11: ...Ring 40 Power Cable 7 Impeller 24 Rotor 41 Cap Nut 8 Casing 25 Bearing 42 Float Switch 9 Bolt 26 Insulation Paper 43 Capacitor 10 Outlet Connector 27 Bottom Bearing Chuck 44 Wave Form Washer 11 Sealin...

Page 12: ......

Reviews: