ELECTRICAL CONNECTIONS
Before switching the pump on, make sure that the
voltage of your electricity supply is the same as that
indicated on the rating plate or on the junction box
cover on top of the motor. This product is designed
to operate on 230VAC 50Hz. Connecting it to any
other power source may cause damage.
Installation should be carried out by a qualified
electrician, using I.E.E approved cable and fittings,
and in accordance with I.E.E. Regulations. However,
in the further interests of safety we would emphasise
the electrical hazard
.
• The BLUE wire must be
connected to the
terminal marked N or
coloured black.
• The BROWN wire must
be connected to the
terminal marked L or
coloured red.
• The YELLOW AND
GREEN wire must be
connected to the
terminal marked E
or
or coloured green.
We strongly recommend that this machine is connected to the mains supply
via a Residual Current Device (RCD).
If in any doubt, consult a qualified electrician. DO NOT attempt any
connections yourself.
WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE
MAINS SUPPLY.
WARNING: WIRES IN THE MAINS LEAD ARE COLOURED IN
ACCORDANCE WITH THE FOLLOWING CODE:
GREEN/YELLOW = EARTH, BLUE = NEUTRAL, BROWN = LIVE.
Plug must be BS1363/A approved.
Always fit
Ensure that the outer sheath of
Neutral
(Blue)
Live
(Brown)
Earth
(Green and
a 13 Amp
the cable is firmly held by the clamp
fuse.
Yellow)