background image

8

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

SETTING THE TEMPERATURE

The operating temperature is 
selected by adjustment of the 
thermostat.

• The hottest setting will be when 

the thermostat is to “6” and the 
power switches are set to 
maximum, the coolest, when it 
is set to “0”.

TIMER FUNCTION

SETTING THE CURRENT TIME

1. Turn the dial clockwise to align 

your current time to the triangular 
pointer. 

SETTING THE TIMER

1. The circumference of the dial is 

composed of 96 segments. Each 
segment represents 15 minutes.

2. The timer is turned ON for 15 

minutes by each activated 
segment 

• Activated segment                

(pulled outwards). 

• Non-activated segment 

(pushed inwards).

Example: To use the timer to turn the radiator on between 04:00 and 05:00.

1. Set current time.

2. Turn the slide switch to timer symbol 

.

3. Pull the 4 segments between 4 and 5 outwards.

Summary of Contents for 6934007

Page 1: ...able for well insulated areas and not designed to be the primary heat source OPERATION MAINTENANCE INSTRUCTIONS LS1119 ISS 5 ORIGINAL INSTRUCTIONS 2 5 KW OIL FILLED RADIATOR MODEL NO OFR13 250 PART NO...

Page 2: ...the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment recycling recovery and environmentally sound disposal of the WEEE In...

Page 3: ...room and or outdoor temperature feedback No Electronic heat charge control with room and or outdoor temperature feedback No Fan assisted output No Type of heat output room temperature control select o...

Page 4: ...objects at least 50cm from the top and sides and front 13 Do not use this oil filled radiator when it is lying on its side 14 If the oil filled radiator is tipped over unplug it and allow it to cool...

Page 5: ...ard If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connecte...

Page 6: ...diator upside down and insert the securing loop as shown 2 Hook the securing loop to the wheel plate and feed the threaded end of the securing loop through the second hole as shown 3 Fix the wheel pla...

Page 7: ...gging in the radiator 2 Plug the radiator into the mains supply 3 Slide the switch on the timer to I if you are going to use the timer to control the radiator skip this step 4 Use the power switches t...

Page 8: ...TION SETTING THE CURRENT TIME 1 Turn the dial clockwise to align your current time to the triangular pointer SETTING THE TIMER 1 The circumference of the dial is composed of 96 segments Each segment r...

Page 9: ...verheating caused by any fault condition which induces a rapid temperature rise In the event of the safety overheat device operating the oil filled radiator will cease to function until the teperature...

Page 10: ...of the oil filled radiator to remove dust and dirt 4 Ensure the oil filled radiator is dry before plugging back into the mains supply 5 Do not allow water to run into the interior of the oil filled ra...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...